© VALLOX

VALLOX 132 E R

Vallox

E

132

Electrical connection

230 V, 50 Hz

Class of protection

IP 34

Fans

Extract air 

210 W 0.91 A (AC) 120 dm

3

/s (120 Pa)

Supply air 

210 W, 0.91 A (AC)110 dm

3

/s (100 Pa)

Heat recovery

Cross-flow cell, n > 60%

Filters

Supply air

G4 and F7

Extract air

G4

Weight

71 kg

Power adjustment

Separate four-step speed selector
or PTXP/i132 cooker hood

Options 132 E/132 E VKL

Filter guard (supply and/or extract air)

Insulated attic floor penetration plate

Ceiling mounting plate Vallox 132 E

VKL expansion tank + stand

VKL heat exchanger pipe
for Vallox 132 VKL

Fireplace switch with 0-120 min.
timer, surface mounting

Fireplace switch with 0-120 min.
timer, flush mounting

Silencer unit

Options VALLOX 132 E

2.7 kW, 12.0 A

Preheating unit

Electric 1200 W, 5.2 A

Post-heating unit Electric 1200 W, 5.2 A

Options VALLOX 132 E VKL

1.55 kW, 6.7 A

Preheating unit

Electric 1200 W, 5.2 A

Post-heating unit VKL water radiator

Speed selection switch

• Cross-flow heat recovery cell

(

>60%)

• Alternating current fans

• 4-step transformer adjustment

• Fireplace/booster function (optional)

• Manual heat recovery cell bypass

during summer

• Fireplace switch function (option)

• Antifrost

• Maintenance reminder

• Good outdoor air filtering (F7)

• Wide selection of radiator options

• Silencer unit (option)

Summary of Contents for 132 E Series

Page 1: ...ic floor penetration plate Ceiling mounting plate Vallox 132 E VKL expansion tank stand VKL heat exchanger pipe for Vallox 132 VKL Fireplace switch with 0 120 min timer surface mounting Fireplace switch with 0 120 min timer flush mounting Silencer unit Options VALLOX 132 E 2 7 kW 12 0 A Preheating unit Electric 1200 W 5 2 A Post heating unit Electric 1200 W 5 2 A Options VALLOX 132 E VKL 1 55 kW 6...

Page 2: ...d one way dampers only in VKL models Air flow measuring outlets behind cover plate Connection ø 12 only in VKL models Electric radiator unit option post heating adjustment VKL model option VKL radiator antifreeze Preheating adjustment Antifrost function of the heat recovery cell Supply air to the dwelling Extract air from the dwelling Outdoor air to the unit Exhaust air outside 4 3 2 1 Model R Exh...

Page 3: ...ir flows Vallox 132 E VKL liquid radiator unit winter setting NOTE If the unit has a post heating radiator it must be selected when the system is adjusted Air flow measurement outlets The fixed air flow measurement outlets are located behind the cover plate You can measure the total pressure of the supply and extract air ductwork at the measurement outlets using a pressure gauge Compare the pressu...

Page 4: ...45 9 66 8 61 4 52 1 44 2 42 7 38 9 31 5 68 0 50 1 66 3 62 9 55 4 46 7 45 0 42 3 34 4 24 3 68 2 52 5 64 1 63 4 59 9 48 7 46 8 45 0 37 1 26 5 69 1 54 2 70 2 65 2 60 0 50 6 48 1 47 1 39 2 32 5 71 8 56 1 70 4 66 9 62 2 52 9 50 2 49 5 41 9 36 3 72 5 58 2 50 3 39 4 31 6 30 3 25 9 17 4 50 8 32 1 1 23 7 2 33 3 3 42 2 4 54 5 5 68 5 6 82 7 7 92 1 8 109 0 11 8 1 20 3 23 2 23 7 2 32 1 35 1 32 8 4 56 8 61 2 36...

Page 5: ...y air ducts after the silencer unit Lw dB Medium frequency of the octave band Hz Sound power level by octave band in extract air ducts after the silencer unit Lw dB ADJUSTMENT POSITION AIR FLOW 63 125 250 500 1000 2000 4000 8000 LW dB LWA dB A 1 16 24 Adjustment position Air flow dm3 s pressure Pa 2 25 47 3 36 70 4 48 90 5 58 104 6 68 116 7 75 131 8 87 148 1 25 7 2 38 7 3 46 46 4 59 69 5 72 79 6 8...

Page 6: ...l the unit by remote monitoring The unit can then be controlled by VALLOX control centre 1993A YK for instance Two speeds and one bypass speed can be chosen at the centre the bypass speed can be used to bypass the two first speeds The standard four step switch can also be replaced with a corresponding control system which must be planned by an expert for each specific case Control with a cooker ho...

Page 7: ...ng radiator performance option Temperature of air coming to the radiator 12 C liquid flow 0 05 dm3 s liquid flow 0 03 dm3 s Power of VKL water radiator Pressure loss in the VKL water radiator 50 dm3 s 0 5 0 25 0 75 90 dm3 s Air flow 1 0 1 25 0 25 30 20 15 12 30 dm3 s 70 dm3 s Temperature of air going out of the unit C Total power of the radiator kW 45 C 35 C 25 C Temperature of water coming to the...

Page 8: ...K 160 V 120 V 230 V 80 V 160 V 230 V 120 V N 100 V 140 V 180 V 40 C T1 R 80 C 80 C V K K 5 6 7 4 3 2 1 13 11 10 9 8 J 1 2 2 N L 4 3 2 1 5 2 1 L 6 N N N L1 L2 W 3 X 1 5 S 230 V N L S E BN BU YE GN BK BN BU YE GN BK SK 2 N N 2 1 1 Electric post heating radiator T6 Overheat protection 30 C automatic T7 Overheat protection 2 pcs 55 C M Transformer K Capacitor 4μF HK Maintenance switch TK Fireplace swi...

Page 9: ...T4 Antifreeze thermostat cell 4 C INTERNAL ELECTRICAL DIAGRAMS VALLOX We reserve the right to make changes without prior notification What the units include can vary depending on the sales area 9 VKL water post heating radiator T5 Preheating radiator regulating thermostat 5 C M Transformer K Capacitor 4μF HK Maintenance switch TK Fireplace switch e g 15 min timer with opening contacts option Mount...

Page 10: ...021300A 3 1 6 DISTRIBUTION PANEL REMOTE MONITORING OPERATION STATUS INDICATION POTENTIAL FREE CONTROL CENTRE 1993A YK OPERATING STATUS DATA VALLOX 132 E VALLOX We reserve the right to make changes without prior notification What the units include can vary depending on the sales area EXTERNAL ELECTRICAL DIAGRAM 10 Cooker hood control 7 x 1 5 S 3 x 1 5 S COOKER HOOD PTXP I 132 1 N CONNECTION BOX VAL...

Page 11: ...e unit is opened Fan speed adjustment The S and E fans of the unit are controlled depending on operating conditions with a speed selector switch NK in four steps Supply air temperature Regulating thermostat T3 controls the operation of electric radiator J keeping the supply air going out from the unit at the setpoint Preheating The preheating radiator can heat outdoor air and decrease the stopping...

Page 12: ...n speed adjustment The S and E fans of the unit are controlled depending on operating conditions with a speed selector switch NK in four steps Supply air temperature Self actuated control valve SV controls the operation of post heating radiator J maintaining the temperature of supply air going out from the unit at the setpoint Preheating The preheating radiator can heat outdoor air and decrease th...

Page 13: ...l easy to use ceiling mounting plate patent pending The ceiling mounting plate is fixed to the ceiling with M8 thread bars Fix the bars so that they stand the weight of the unit i e approximately 71 kg The ceiling mounting plate has to be fixed horizontally in order to ensure that the unit will be straight The outdoor air duct must be insulated against condensation also between the unit and the ce...

Page 14: ...y connecting a pipe to the water seal the water condensing from extract air can be led to a floor drain The pipe must never be con nected directly to the drain The condensing water pipe must have a downward slope The unit comes with separate instructions for mounting and using the water seal Top part of wall bracket Bottom part of wall bracket Wall bracket mounted VALLOX 132 E wall mounting 17 5 4...

Page 15: ...ure of heating water shall be adjusted according to the temperature of outdoor air No water must be led into the radiator of the unit until the system has been adjusted for operation and the heating network has heating on or it has been otherwise ensured that the radiator will not freeze Water circulation in the heating network connected to the unit and the circulation pump must not be stopped dur...

Page 16: ...VALLOX 132 E www vallox com VALLOX We reserve the right to make changes without prior notification What the units include can vary depending on the sales area 1 09 409E 3 10 2012 PDF ...

Reviews: