INITIALIZING THE INCHING SENSOR
Start engine after parking the truck on flat floor and blocking wheels.
Release parking brake and keep neutral gear shift.
Adjust the inching sensor linkage so that the regular voltage is supplied to inching sensor when
operating the pedal.
Regular voltage ; Before pedal operation (1
Ü
0.1V), After pedal operation (3.5
Ü
0.1V).
Stop the engine and then just start switch ON. (Release parking brake, keep neutral gear)
Connect the AEB STARTER to the T/M controller.
Push AEB STARTER over 3 seconds.
If display shows "
ă
IP", Step on the pedal fully.
If display shows "
ā
IP", release "OK"
After the successful completion, it displays "OK".
In case of abnormal running, it may display "STOP" with the appropriate error code.
After troubleshooting, start the truck again to repeat above.
Above works are to be done with the parking brake released, so truck's wheels must be blocked
for safety.
(1)
(2)
(3)
ö
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
ö
3)
DISPLAY DURING INCHPEDAL CALIBRATION
4)
Symbol
Meaning
Remarks
ă
IP
Push down the pedal slowly until endposition
is reached and hold this position
ā
IP
Release the pedal slowly until endposition is
reached
IP blinkt
A problem occurred, release the pedal
slowly until endposition is reached
If the expected endposition could not be
reached, release the pedal and try again
OK
Finished inchpedal calibration successful
FN and Stop
Shift lever not in Neutral position
Calibrations is aborted
FS and Stop
Sensor supply voltage AU1 is out of the
specified range
Calibrations is aborted
FO and Stop
Outputspeed_not_zero
Calibrations is aborted
SL and Stop
Sensor voltage below specified range
Calibrations is aborted
SU and Stop
Sensor voltage below specified range
Calibrations is aborted
IL and Stop
Sensor position for released pedal out of
specified range
Calibrations is aborted
IU and Stop
Sensor position for released pedal out of
specified range
Calibrations is aborted
TO and Stop
Time-out calibration, pedal not moved after
calibration start
Calibrations is aborted
DL and Stop
Angle between pedal positions released and
pressed to small
Calibrations is aborted
DU and Stop
Angle between pedal positions released and
pressed to small
Calibrations is aborted
FI and Stop
Sensor signal 1 and 2 don't match together
Calibrations is aborted