0-9
START PROCEDURE
START PROCEDURE (Item 28)
This warning label is positioned on the right
window inside of cabin.
The fuel transter pump is self-priming.
When the start switch is in ON position,
the fuel transter pump operates for 2
seconds & then shuts off.
Wait up to 45 sec for grid heater
operation depending on ambient
temperature.
Start cranking.
If the engine would not start, release the
start switch to ON position for fuel
transfer pump operation for 25 seconds.
If the engine still does not start, turn the
start switch to OFF position, and loosen
the banjo bolt of injection pump at the
fuel supply line.
Repeat the previous steps until fuel is
exiting at the supply line.
Tighten the banjo bolt at the supply line.
Re-cranking.
If the engine still would not start, please
contact the nearest HYUNDAI or
Cummins dealers.
8)
8)
91LC-11170
START WARNING
START WARNING (Item 13)
This warning label is positioned on the
middle top side of dashboard cover.
Start engine after 5~6 seconds from ON
Start engine after 5~6 seconds from ON
position. It needs approx 5~6 seconds to
position. It needs approx 5~6 seconds to
set correct position of throttle.
set correct position of throttle.
Warnings before leaving the operator seat.
Be sure to lower the attachment to the
ground.
Apply the parking brake.
Cautions before starting or operating the
truck.
Put the gear selector lever in the neutral.
Apply the parking brake.
Read this operator's manual carefully.
92AD-00920
P
5 6’
~
I
9)
9)
※
1.
50DEFW55
-
-
2.
-
-
-
1.
2.
3.
4.
5.
6.
7.
8.