TR-800 Service Manual
61
Circuit Detect and Temperature-control Test
Connect CN0201 (to Power Supply) and CN0204 (to Ext. Battery) with DC power output 13.8V respectively.
Measure Adjustment
Procedure Condition
Instrument
Testing
Point
Adjusting
Point
Method
Specification/Remark
AC to DC
over-voltage
detect
/
Digital
voltmeter
CR0219
CN0201
Increase or decrease the input voltage
When the voltage of CN0201 is
gradually increased to 16.4V, the
protection circuit will drive KR01 to
revert to DC power supply. When the
voltage of CN0201 is decreased to
13.4V, AC power supply returns.
AC mains fail
detect
/
/
CR0219
CN0201
Close or open input voltage
Remove the voltage of CN0201, driving
KR01 to revert to DC power supply with
CR0219 illuminating; Apply voltage to
CN0201, activating KR01; AC power
supply returns with CR0219 going out.
Battery low
detect
Close CN0201 voltage
Digital
voltmeter
CR0219,BA
T LOW
CN0204
Raise or lower input voltage
Gradually decrease the voltage of
CN0204 to 10.2V, driving KR01 to cut
down DC power supply, with CR0219
going out. “BAT LOW” outputs low
pulse. Apply voltage to CN0201, with
CR0219 flashing briefly, then AC power
supply returns; remove the voltage of