TR-800 Service Manual
55
Adjustment Description
Logic Board Adjustment
Required Test Instruments
1.
20A/30V
Power
Supply 1set
2. Ammeter
1set
3. Digital Voltmeter
1set
4. Test Jumper Cables (mating with test ports of TR-800 and the communication test set)
5. Communication System Analyzer (
CSA
such as HP8921 series) 1set
Adjustment
Radio Configuration
Use HR-800PE to program TR-800. Table and table illustrate the factory default settings in a
Ⅰ
Ⅱ
general operation mode. The “Ignition Sense Time” of the master radio defines time delay from SETUP
to KNOCKDOWN.
Table
Radio Programming Preset
Ⅰ
Item
Master radio
Slave Radio
AUX3 I/O
Ext. PTT
Ext. PTT
AUX4 I/O
NA
AFO for Filtered Audio Path
DEO for Flat Audio Path
AUX5 I/O
Rx Tone(Carrier)
Rx Tone(Carrier)
Horn Alert Logic Signal
NA
1s for REPEATER STUN enable
Until Reset for REPEATER STUN disable
Ignition Sense
0h0m
NA
Drop Out Delay
1000ms
Scan Gap Time
180ms
Repeater Hang Time
1s
Table
Logic Board Switch Configuration
Ⅱ
:
Toggle Switch
S01-1 S01-2 S01-3
S01-4
S01-5
S01-6
S01-7
S01-8 S01-9
S01-10
Factory Default
ON ON OFF ON ON ON ON ON OFF ON