background image

Operating Instructions & Parts Manual

 

RMC-FA300PF

ProFitter

TM

Propane Construction Heater

Description

ProFitter

TM

 Model RMC-FA300PF heaters are 300,000 BTU/Hr construction heaters. 

This heater uses propane gas for combustion, and electricity to run the fan. It 
is primarily intended for temporary heating of well-ventilated buildings under 
construction, alteration or repair. This heater should be utilized in sheltered, well-
ventilated areas, but never in occupied dwellings.

C           US

C                        US

  

Output Rating 

 

Maximum Fuel 

 

Regulator 

 Model 

BTU/Hr 

Fuel 

Consumption 

Ignition 

Outlet Pressure

RMC-FA300PF 

300,000 

Propane Vapor Only 

13.9 lb/h 

Direct Spark, Interrupted 

  7-10 PSIG

  

Hot Air Output  

Minimum Supply 

Maximum Supply 

Size 

 

 Model 

Approx. (CFM)    Motor 

Pressure to Regulator 

Pressure to Regulator  L x W x H (Inches) 

3VE59C            

RMC-FA300PF 

0.085 HP 

  25 PSIG  

(For purposes             

Max Bottle Pressure 

33.7 x 12.6 x 20.5 

  

 

  1,720 RPM  of input adjustment) 

 

 

Table of Contents 

Page

Description  . . . . . . . . . . . . . . . . . . . . . . .1
Specifications. . . . . . . . . . . . . . . . . . . . . .1
Unpacking . . . . . . . . . . . . . . . . . . . . . . .  1
General Safety Information . . . . . . . . 1-3
Theory of Operation. . . . . . . . . . . . . . . .3
Installation. . . . . . . . . . . . . . . . . . . . . . 3-5
Ventilation. . . . . . . . . . . . . . . . . . . . . . . .5
Operation  . . . . . . . . . . . . . . . . . . . . . . . .6
Maintenance . . . . . . . . . . . . . . . . . . . . 5-6
Storage  . . . . . . . . . . . . . . . . . . . . . . . . . .6
Wiring Diagram. . . . . . . . . . . . . . . . . . . .6
Repair Parts Illustration
and Parts List . . . . . . . . . . . . . . . . . . . . 8-9
Troubleshooting Chart . . . . . . . . . . . . .10
Warranty  . . . . . . . . . . . . . . . . . . . . . . . .10

Unpacking

1. Unpack all materials used to protect 

the heater inside of carton. Retain 
plastic caps attached to exposed 
fittings for use during storage.

2. Remove heater, accessories and all 

hardware from carton.

3. Inspect all items for damage that may 

have occurred during shipment.

GENERAL HAZARD 

WARNING

FAILURE TO 

COMPLY WITH THE PRECAUTIONS AND 

INSTRUCTIONS PROVIDED WITH THIS 

HEATER, CAN RESULT IN DEATH, SERIOUS 

BODILY INJURY AND PROPERTY LOSS, 

OR DAMAGE FROM THE HZARARDS OF 

FIRE, EXPLOSION, BURN. ASPHYXIATION, 

CARBON MONOXIDE POISONING, AND/

OR ELECTRIC SHOCK.

ONLY PERSONS WHO CAN UNDERSTAND 

AND FOLLOW THE INSTRUCTIONS 

SHOULD USE OR SERVICE THIS HEATER.

IF YOU NEED ASSISTANCE OR HEATER 

INFORMATION SUCH AS AN INSTRUCTION 

MANUAL, LABELS, ETCETERA, CONTACT 

THE MANUFACTURER.

General Safety Information

IMPORTANT: Be sure to read and 

understand all cautions and warnings, 

before operating this heater. Keep 

this instruction manual for future 

reference, and use it as a guide to safe 

and proper operation of the heater. 

Various precautions appear throughout 

this manual. Please review and pay 

close attention to them. Below is an 

explanation of the various levels of 

caution required while operating this 

heater.

DANGER

Indicates  an  im minen tly 

hazardous situation 

which, if not avoided, WILL result in death 

or serious injury. 

 

WARNING

Indicates a poten tially 

hazardous situation 

which, if not avoided, COULD result in 

death or serious injury. 

CAUTION

Indicates a poten tially 

hazardous  situa tion 

which, if not avoided, MAY result in minor 

or moderate injury.

FIRE, BURN, 

INHALATION, AND 

EXPLOSION HAZARD, KEEP SOLID     
COMBUSTIBLES, SUCH AS BUILDING

  

 Model 

 Electrical Input 

Amperage 

RMC-FA300PF 

     120 V, 60 Hz 

      0.65

Electrical Specifications

General Specifications

(6.3 kg/h)

(85.6 x 32 x 52.1 cm)

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and 
others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for 
future reference.

Specifications

Printed in China

Figure 1 – Model RMC-FA300PF

E

N
G

L

I

S

H

E
S
P

A
Ñ
O

L

F

R

A
N

Ç

A

I

S

ANS Z83.7-2017 CSA 2.14-2017  

CONSTRUCTION HEATER

 

 

 

   

 

               

IMLPF300PF - LCU

Summary of Contents for RMC-FA300PF

Page 1: ...OPERTY LOSS OR DAMAGE FROM THE HZARARDS OF FIRE EXPLOSION BURN ASPHYXIATION CARBON MONOXIDE POISONING AND OR ELECTRIC SHOCK ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTION MANUAL LABELS ETCETERA CONTACT THE MANUFACTURER General Safety Information IMPORTANT Be sure to read and understan...

Page 2: ...ces a small amount of carbon monoxide Humans can tolerate small amounts of carbon monoxide for short periods Carbon monoxide can build up in a heated space and failure to provide adequate ventilation could result in poisoning or death For either indoor or outdoor use Adequate ventilation shall be provided in accordance with OSHA 29 CFR 1926 154 Safety Requirements for Temporary and Portable Space ...

Page 3: ... SAFETY CONTROL SYSTEM This system shuts the heater down if the flame is extinguished The fan and motor will continue to operate butthere will not be any heat PROPANE SUPPLY All propane gas and tanks are to be provided by the user This heater should only be used with a tank that has a vapor withdrawal system Refer to the Standard of Storage and Handling of Liquefied Petroleum Gas ANSI NFPA 58 Chap...

Page 4: ...ns Correct all leaks immediately 7 Close propane supply valve Ventilation Always follow the minimum fresh air ventilation requirements If these guidelines are not followed carbon monoxide poisoning can occur Always provide proper amounts of fresh air before operating this heater Provide at least three square feet 0 28 m of fresh outside air for each 100 000 BTU Hr of rating This heater requires a ...

Page 5: ... and Ontario Workplaces Reg 833 25 ppm 5000 ppm 3 ppm Reg 833 Canada STEL 15 minutes Reg 833 1 hour WSBC WorkSafe BC OHS Guidelines Part 5 1 and Ontario Workplaces Reg 833 100 ppm 15000 ppm WSBC 30000 ppm Reg 833 1 0 ppm WorkSafeBC 5 0 ppm Reg 833 Ensure that the flow of combustion and ventilation air exchange cannot become obstructed As the building tightens up during the construction phases vent...

Page 6: ...eset and you can try to light the heater once again TO SHUT DOWN HEATER 1 Tightly close control valve on propane tank s 2 Give the heater a few seconds to burn the gas still left in the hose 3 Turn on off switch to the OFF position 4 Unplug extension cord from power source TO RESTART HEATER NOTE If the safety control stops the flow of gas to the heater the motor will continue to run To restart the...

Page 7: ...ft replace fan as shown in Figure 7 Tighten setscrew firmly be careful not to overtighten 10 Reconnect lead wires as shown in the Wiring Diagram Figure 8 11 Reassemble base fan guard and base lower IGNITOR The only maintenance necessary for the ignitor is to be sure that the gap between the electrodes is kept between 10 and 15 2 5 3 8 mm The ignitor is accessible through the combustion chamber Sto...

Page 8: ...ing Instructions and Parts Manual RMC FA300PF If any original wiring as supplied with the heater must be replaced it must be replaced with type AWG105 C wire or its equivalent except as indicated Type SF2 200 SGI 250 C Figure 8 Wiring Diagram NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING E N G L I S H ProFitterTM Propane Construction Heater For Technical Support or Troubleshooting Call 1 877 447...

Page 9: ...Notes ProFitterTM Operating Instructions and Parts Manual RMC FA300PF NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING For Technical Support or Troubleshooting Call 1 877 447 4768 8 30 am 4 30 pm CST www ghpgroupinc com ...

Page 10: ...55 56 57 58 24 23 22 12 20 14 13 15 16 17 18 19 21 7 9 10 11 8 26 For Technical Support or Troubleshooting Call 1 877 447 4768 ProFitterTM Dyna GloTM Operating Instructions and Parts Manual 10 ProFitterTM Operating Instructions and Parts Manual RMC FA300PF NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING For Repair Parts call 1 877 447 4768 Please provide following information Model number Serial n...

Page 11: ...01633 1 34 Power Cord Assembly 2201163 1 35 Switch 2201549 1 36 Solenoid Valve 2315449 1 37 Screw 2001206 2 38 Connector Inlet 2315595 1 39 Fitting 2315596 1 40 Solenoid Valve Bracket 2315594 1 41 Screw 2000416 2 42 Nut 2000384 2 43 Back Pressure Switch 2201594 1 44 Base Lower 2315589 1 45 Screw 2001355 6 46 PCB Assembly 2201181 1 47 Screw 2001445 2 48 Nut 2000231 2 49 Base 2315588 1 50 Plastic Tu...

Page 12: ...r cord and extension cord for cuts and breaks 2 Be sure that housing is not damaged Make sure there are no obstructions to the fan 3 Straighten blade s to match others 4 Replace motor 1 Check igniter wire Reattach or tighten if loose Check spark module Replace if necessary Check all electrical components 2 Set gap to 0 08 2 mm 3 Replace spark plug 1 If the heaters output is restricted internal tem...

Page 13: ...how long an implied warranty lasts so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you CLAIMS HANDLED AS FOLLOWS 1 Contact your retailer and explain the problem 2 If the retailer is unable to resolve the problem contact ourCustomer Service Dept detailing th...

Page 14: ...s SAVE THIS CARD Place Postage Stamp Here GHP Group Inc 8280 Austin Avenue Morton Grove IL 60053 3207 GHP Group Inc 8280 Austin Ave Morton Grove IL 60053 3207 Tel 877 447 4768 www ghpgroupinc com 8280 Austin Avenue Morton Grove IL 6 0 0 5 3 3 2 0 7 Tel 847 324 5900 Fax 847 324 5901 Toll Free 877 GHP Group 8 7 7 4 4 7 4 7 6 8 www ghpgroupinc com GHP GHP Group Inc 6440 W Howard St Niles IL 60714 330...