TR-800 Service Manual
34
70. Close the “Per Channel - n” window.
71. Double click on the “Per Zone - 1” option from the treeview menu of “Per Zone”.
72. Select the “Zone Channel List” tab.
73. Click the
Add
or
Insert
button to add a channel or
Del
button to delete it. All the channels here
should be programmed into the repeater. Assign the desired channel to “Channel” option. Verify the
number of channels is equivalent to that of the slave radio. Your screen will be shown in Figure 6-28.
Figure 6-28
74. Close the “Per Zone-n” window.
75. Double click on the “Duplex” option from the opened HR800PE treeview window.
76. Enter a “Radio Power on Message” that will be displayed, such as “TR-800 Rpt”.
77. Click the drop down menu to select a desired “Repeater Hang Time” in steps of 100 millisecond.
78. Click the drop down menu of Scan Gap Time[ms]. Select an appropriate time interval based on field
test. If necessary, change the “Dropout Delay Time[s]” in steps of 100 millisecond as per your
requirements. Note that repeater scan is only active in forward directional repeater, i.e. RPT is
enabled and OPT is disabled via front panel button configuration. Your screen will be shown in
Figure 6-29.
79. Check the box beside “Battery Revert Emergency Select” to enable remote emergency alert via the
transmitter once the AC mains fails and the back-up battery system will apply. This is an optional
function and applies only if you have back-up power system which will engage in case of power
outage.
Summary of Contents for TR-800
Page 17: ...TR 800 Service Manual 15 Figure 6 5 Figure 6 6 ...
Page 41: ...TR 800 Service Manual 39 Figure Ⅰ Block Diagram ...
Page 81: ...TR 800 Service Manual 79 Packing ...
Page 82: ...TR 800 Service Manual 80 TR 800 Wiring Diagram ...
Page 83: ......
Page 84: ......
Page 85: ......
Page 86: ......