Installation and Maintenance Manual
27
20. Free Exit Loop Vehicle Detector output (available with h3.23 and higher software):
This output is active
whenever the ELD is tripped.
21. Inside Obstruction Vehicle Detector output (available with h3.23 and higher software):
This output may
be used to interlock to an exit device to prevent pedestrian use. This output is active whenever the IOLD is
tripped.
22. Reset Loop Vehicle Detector output (available in h3.23 and higher software):
This output is active
whenever the RLD is tripped.
23. Gate Lock Output (available in h3.26 and higher software):
External gate lock output. Activates at initiation
of open cycle and remains on for 10 seconds. Similar to #6 but shuts off after 10 seconds.
24. Gate at Partial Open Position (available in h3.26 and higher software):
This output is active when the
partial open position is reached or exceeded.
Clock Functions
Setting the Time and Date
The Smart Touch Controller is equipped with a 24 hour (military time), 365 day clock, so that events of significance
can be logged and stamped with both the time and the date. This feature is useful to record key historical
operational data and a log of Alerts, Faults and Errors all of which can be accessed via the RS232 port. Optional
software and a serial communication cable are required in order to read this data*.
1. To set or adjust the time, go the User menu item [CL_0] and push the
Select
button
, so that [CL_0] blinks.
Using the
Previous
and/or
Next
buttons, change the setting from [CL_0] to 1, 2, 3 or 4 depending upon
which setting is to be changed. 1 = minutes / 2 = hours / 3 = days / 4 = months.
2. Push
the
Select button.
The display will change to a blinking (adjustable) value. Different displays will
appear (see table below) based on which [CL] value is selected:
Setting Value
Display
[CL 1]
minutes
[ni 0–59]
[CL 2]
hours
[hr 0–23]
[CL 3]
days
[dA 1-31]
[CL 4]
months
[no 1-12]
[CL 0]
Run Mode
None
3. Change the hour, minute, day or month to the desired value using the
Previous
and/or
Next buttons
, then
press the
Select
button
to enter the change. [CL 0] will appear.
4. To change another setting, Press the
Select button,
(display will blink), then move to that setting using the
Previous
and /or
Next
buttons and repeat steps 2 and 3 until the clock is fully set.
5. When finished, be sure [CL 0] is displayed, then push
MENU
to exit.
6. A lithium disk battery supports the clock so that the time is not lost when the main power is off. This battery
should be replaced about every five years. Use a DL 2025 / DL 2032 or
CR 2025 / 2032 battery.
*
START
Configuration and Diagnostic software is available at no charge from our website – www.hysecurity.com.
Serial communication cables (P/N ESR00024) as well as Serial to USB adaptors (if needed) are available through
HySecurity distributors (Cable and USB Adaptor Kit P/N MX000667)
.
Summary of Contents for HTG 320-2
Page 18: ...Installation and Maintenance Manual 10 Components of the Barrier Arm Gate Operator ...
Page 21: ...Installation and Maintenance Manual 13 46 ...
Page 22: ...Installation and Maintenance Manual 14 46 ...
Page 23: ...Installation and Maintenance Manual 15 ...
Page 43: ...Installation and Maintenance Manual 35 E95 ...
Page 48: ...Installation and Maintenance Manual 40 24 hr 7 day Timer Connection to Smart Touch Controller ...
Page 57: ...Installation and Maintenance Manual 49 24V 110A H BATTERY POWER SUPPLY FOR DC OPERATORS ...
Page 59: ...Installation and Maintenance Manual 51 ...
Page 60: ...Installation and Maintenance Manual 52 Parts Breakout ...
Page 61: ...Installation and Maintenance Manual 53 Parts Breakout ...
Page 62: ...Installation and Maintenance Manual 54 Parts Breakout AC Pumps MX000234 HVABY 000 CRT ...
Page 63: ...Installation and Maintenance Manual 55 Parts Breakout DC Pumps MX000234 HVABY 000 CRT ...
Page 64: ...Installation and Maintenance Manual 56 Parts Breakout ...
Page 67: ...Installation and Maintenance Manual 59 Smart Touch Controller Connections ...
Page 68: ...Installation and Maintenance Manual 60 Quick StrongArm Brake Valve adjustment Procedure ...