Installation and Maintenance Manual
22
Smart Touch Controller Installer Menu Functions
The Installer Menu can be accessed only by entering the User Menu first, and then by
pressing the
Reset button and the Open button
simultaneously (some older software requires the Reset button
be pressed first and held while the Open button is pressed).
The following table is the menu options for the HTG 320 Barrier Arm gate. Note that this menu adds
several items not used in our other gate operators. The most useful additions are several optional
control functions for the Reset Loop Detector, which is the loop directly under the barrier arm. Note:
I
18 [Cr__] Controls whether the reset loop stops only or reverses for a tailgating vehicle.
I
19 [Cb__] Allows bi-directional use by disabling the free exit loop when a vehicle enters.
I
20 [CP__] Adds an open input counting function that allows the arm to stay open until a 2
nd
car exits.
This is useful to not trap the 2
nd
vehicle if the open input has some kind of anti-passback function.
I
21 [Eb__] Allows the free exit loop to generate a close command when cleared.
Installer Menu Options
Default
Description
I1
[uC 0] Set UL Usage Class
0
0 = Gate disabled, Set Class 1 through 4 use
I1a
[bu 0] Choose Buzzer
0
0 = Buzzer not set, 1 = Freq 1, 2 = Freq. 2
I2
[Fd 0] Load Factory Defaults
0
0 = User Settings, 1 = Load defaults (resets entire menu)
I3
[dg 0] Set Master/Slave type
0
0 = Solo operator, 1 = Slave unit, 2 = Master unit
I4
[Ch 0] Set AC Charger or Solar
0
0 = DC + AC charger, 1 = DC + Solar charger
I5
[Fo 0] Enable Fire Dept. Open
0
0 = input disabled, 1 = enabled
I6
[oC 0] Enable Emergency close
0
0 = input disabled, 1 = enabled
I7
[SE 3] Inherent Sensor sensitivity
3
1 = Maximum sensitivity, 9 = Lowest sensitivity
I8
[SS 0] Inherent Sensor function
0
1 = stop only (note, functions in usage class 4 only)
I9
[LC 0] Leaf delay Close
0
0 = none (1-7) ½ second steps (Master/Slave only)
I10
[Lo 0] Leaf delay Open
0
0 = none (1-7) ½ second steps (Master/Slave only)
I11
[rt 0] Maximum run timer
0
0 = 60 Seconds max run, 1 = 300 Seconds max run
I12
[EC 0] PEC reverse to open
0
0 = Close eye stops only, 1 = 2 sec reverse to open
I13
[PC 0] Set PEC output – NO/NC
0
0 = Normally Open PE output, 1 = N.C. (Supervised mode)
I14
[gC 0] Set Edge input – NO/NC
0
0 = Normally Open Edge output, 1 = Normally Closed
I15
[tC 1] Time clock/ Interlock input
1
0 = select Time Clock, 1 = select Open Interlock
I15a
[dt 0]
Disable Free Exit/Close Tmr
0
0 = disable Free Exit, 1 = disable Close Timer
I16
[or 1] OOLD detector function
1
0 = pause closing only, 1 = enable reversing to open
I17
[ir 1] IOLD detector function
1
0 = pause closing only, 1 = enable reversing to open
I18
[Cr 1] RLD -Reset detector function
1
0 = Reopen if tripped while closing, 1 = Pause only
I19
[Cb 0] RLD -Reset detector function
0
0 = One way, 1 = Bi-directional - disables ELD if tripped first
I20
[CP 0] RLD -Reset detector function
0
0 = Std. Close, 1 = Count opens & closes after equal reset
I21
[Eb 0] ELD –Exit detector function
0
0 = Off, 1 = Enable ELD back off auto close feature
I22
[r1 0] User relay 1 option
1
0 = disabled, 1 – 24 = see relay output options page 26
I23
[r2 0] User relay 2 option
6
0 = disabled, 1 – 24 = see relay output options page 26
I24
[r3 0] User relay 3 option
1
0 = disabled, 1 – 24 = see relay output options page 26
I25
[tL 0] Gate Open alert
2
0 = 0 sec, 1= 15s, 2= 45s, 3= 75s, 4= 105s, 5= 135s
I26
[Lt 0] Loitering alert
3
0 = 0 sec, 1= 15s, 2= 45s, 3= 75s, 4= 105s, 5= 135s
I27
[ELd0] Test factory ELD
0
0=Run, 1=show freq, 2=show call level 0-7, 3= set Freq 1-4
I28
[iLd0] Test factory IOLD
0
0=Run, 1=show freq, 2=show call level 0-7, 3= set Freq 1-4
I29
[oLd0] Test factory OOLD
0
0=Run, 1=show freq, 2=show call level 0-7, 3= set Freq 1-4
I30
[rLd0] Test factory RLD
0
0=Run, 1=show freq, 2=show call level 0-7, 3= set Freq 1-4
These Notes Refer to the Menu Above:
I1
This setting must be configured or the gate cannot function and menu will not exit.
I4
This setting appears only if the factory has provided a DC powered gate operator
I8
IES stop only setting [SS __] does not appear unless set as a class 4 operator
I9-10 These settings appear only if the Installer Menu is set for Master / Slave function
I25-26 These settings appear only if the Installer Menu has set relays
r1-r3
for these alerts
Summary of Contents for HTG 320-2
Page 18: ...Installation and Maintenance Manual 10 Components of the Barrier Arm Gate Operator ...
Page 21: ...Installation and Maintenance Manual 13 46 ...
Page 22: ...Installation and Maintenance Manual 14 46 ...
Page 23: ...Installation and Maintenance Manual 15 ...
Page 43: ...Installation and Maintenance Manual 35 E95 ...
Page 48: ...Installation and Maintenance Manual 40 24 hr 7 day Timer Connection to Smart Touch Controller ...
Page 57: ...Installation and Maintenance Manual 49 24V 110A H BATTERY POWER SUPPLY FOR DC OPERATORS ...
Page 59: ...Installation and Maintenance Manual 51 ...
Page 60: ...Installation and Maintenance Manual 52 Parts Breakout ...
Page 61: ...Installation and Maintenance Manual 53 Parts Breakout ...
Page 62: ...Installation and Maintenance Manual 54 Parts Breakout AC Pumps MX000234 HVABY 000 CRT ...
Page 63: ...Installation and Maintenance Manual 55 Parts Breakout DC Pumps MX000234 HVABY 000 CRT ...
Page 64: ...Installation and Maintenance Manual 56 Parts Breakout ...
Page 67: ...Installation and Maintenance Manual 59 Smart Touch Controller Connections ...
Page 68: ...Installation and Maintenance Manual 60 Quick StrongArm Brake Valve adjustment Procedure ...