Install An Automatic Barrier Arm Gate Operator Only When:
The operator will be properly electrically grounded and the intended supply voltage matches
the voltage label on the operator.
The controls that operate the gate have been mounted far enough away from the moving
gate such that users cannot touch the gate while operating the controls. All easily
accessible controls must have a security feature to prevent unauthorized use.
The operator controls will be located in a clear line-of-sight to the gate. Radio controls and
other remote access controls must be connected only to the
Remote Open input.
The required external entrapment sensors will also be installed. Be certain to carefully
review the instructions for placement, installation and adjustment of these external
entrapment sensors. If edge (contact) sensors are used, they are to be mounted on the
bottom edge, of the arm. If photo eyes or other non-contact sensors are used, they are to
be mounted in locations most likely to guard against entrapment. A combination of contact
and non-contact sensors may be used, but all must be recognized components under the
UL 325 standard. See pages 34 and 35 for details on the requirements.
If the Entrapment protection is provided by a continuous pressure actuation control, a
placard stating “WARNING” – “Moving Gate has the Potential of Inflicting Injury or Death -
Do Not Start Gate Unless Path is Clear.” Additionally, no other activation device shall be
connected and an automatic closing device of any kind shall not be used.
The automatic operator is labeled as appropriate for both the type and UL usage class of
the gate.
Class I: Intended to serve single to four family residential uses
Class II: Multi-family use, or any application intended to serve the general public
Class III: Commercial applications
not
intended to serve the general public
Class IV: Highest security. Security personnel prevent unauthorized access
The barrier arm must not be installed in a manner that will move toward a rigid object closer
than two feet.
Summary of Contents for HTG 320-2
Page 18: ...Installation and Maintenance Manual 10 Components of the Barrier Arm Gate Operator ...
Page 21: ...Installation and Maintenance Manual 13 46 ...
Page 22: ...Installation and Maintenance Manual 14 46 ...
Page 23: ...Installation and Maintenance Manual 15 ...
Page 43: ...Installation and Maintenance Manual 35 E95 ...
Page 48: ...Installation and Maintenance Manual 40 24 hr 7 day Timer Connection to Smart Touch Controller ...
Page 57: ...Installation and Maintenance Manual 49 24V 110A H BATTERY POWER SUPPLY FOR DC OPERATORS ...
Page 59: ...Installation and Maintenance Manual 51 ...
Page 60: ...Installation and Maintenance Manual 52 Parts Breakout ...
Page 61: ...Installation and Maintenance Manual 53 Parts Breakout ...
Page 62: ...Installation and Maintenance Manual 54 Parts Breakout AC Pumps MX000234 HVABY 000 CRT ...
Page 63: ...Installation and Maintenance Manual 55 Parts Breakout DC Pumps MX000234 HVABY 000 CRT ...
Page 64: ...Installation and Maintenance Manual 56 Parts Breakout ...
Page 67: ...Installation and Maintenance Manual 59 Smart Touch Controller Connections ...
Page 68: ...Installation and Maintenance Manual 60 Quick StrongArm Brake Valve adjustment Procedure ...