Appendix B – CnC interfACe protoCol
HPR400XD Auto Gas –
806160
b-11
command table (6 of 14)
ID
command
System
Description
087 BROADCAST MODE
Manual gas system
Auto gas system
Tell all systems to listen but not respond.
Data:
None
Return value:
None
Sample:
>0879F<
no response
094 READ_GAS_PRESSURES
Manual gas system
Auto gas system
Read the gas pressures.
Data:
None
Return value:
Plasma cutflow pressure (psi),
Plasma preflow pressure (psi),
Shield cutflow pressure (psi),
Shield preflow pressure (psi),
Cut gas 1 pressure (psi),
Cut gas 2 pressure (psi),
N
2
Mix inlet pressure (psi),
Gas2 Mix inlet pressure (psi)
space-delimited
Values are in psi (0007 = 7 psi)
Sample:
>0949D<
>094PC0007 PP0036 SC0016 SP0003 CG0000
CG0000 MV0000 MV00005D<
095 SET_ALL_PARAMETERS
Auto gas system
Set all variables to run the plasma system.
If inlet gases
change power supply will enter the purge state. gas
type changes are not allowed when the system is
cutting (state 4 – state 10).
N
2
mix setpoint and Gas 2 mix setpoint are only applicable
when using a mixed plasma gas such as H35 – N
2
otherwise
these 2 values should be set to 0.
A value of 0 for N
2
Mix setpoint will cause the system to close
SV12, the solenoid valve for N
2
mixing. A value of 0 for Gas 2
Mix Setpoint will cause the system to close SV13 and open
SV14. This will cause the inlet gas to bypass motor valve 2
and pass directly to the outlet of the mixing console.
Data:
Current setpoint (5 – 130/260/400 amps),
Corner current percent (50 - 100%),
Plasma gas type code (use table VI),
Shield gas type code (use table VI),
Plasma cutflow setpoint (0 – 99 psi),
Plasma preflow setpoint (0 – 99 psi),
Shield cutflow setpoint ( 0 – 99 psi),
Shield preflow setpoint (0 – 99 psi),
N
2
mix setpoint (0 – 100 psi),
Gas 2 mix setpoint (0 – 100 psi),
space-delimited.
Return value:
1= accepted, 0 = not accepted
Sample:
>095100 75 1 6 55 45 35 25 00 0084<
>0951CF<
Summary of Contents for HyPerformance HPR400XD
Page 1: ...HyPerformance Plasma HPR400XD Auto gas Instruction manual 806160 Revision 4 ...
Page 26: ...Specifications 2 2 HPR400XD Auto Gas 806160 ...
Page 48: ...Installation 3 10 HPR400XD Auto Gas 806160 ...
Page 53: ...Installation HPR400XD Auto Gas 806160 3 15 Horizontal RHF mounting Vertical RHF mounting ...
Page 57: ...Installation HPR400XD Auto Gas 806160 3 19 This page is blank intentionally ...
Page 65: ...Installation HPR400XD Auto Gas 806160 3 27 7 8 8 7 ...
Page 100: ...Installation 3 62 HPR400XD Auto Gas 806160 ...
Page 107: ...Operation HPR400XD Auto Gas 806160 4 7 Diagnostic screen ...
Page 108: ...Operation 4 8 HPR400XD Auto Gas 806160 Test screen ...
Page 109: ...Operation HPR400XD Auto Gas 806160 4 9 Cut chart screen ...
Page 197: ...Operation HPR400XD Auto Gas 806160 4 97 ...
Page 287: ...7 4 HPR400XD Auto Gas 806160 Discrete output functionality ...
Page 347: ...Appendix B CNC Interface Protocol b 28 HPR400XD Auto Gas 806160 ...
Page 355: ...4 HPR400XD Auto Gas 806160 ...