InstallatIon
HPR400XD Auto Gas –
806160
3-53
torch coolant requirements
Premixed coolant for standard operating temperatures
torch coolant requirements
The system is shipped without any coolant in the tank. Before fi lling the coolant system, determine what coolant mix is
correct for your operating conditions.
Observe the warning and cautions below. Refer to the
Material Safety Data Sheets
appendix
for data on safety,
handling, and storage of propylene glycol and benzotriazole.
DANgER
coolANt cAN bE IRRItAtINg to SkIN AND EyES AND
HARMFUl oR FAtAl IF SwAllowED
Propylene glycol and benzotriazole are irritating to skin and eyes, and harmful or fatal if
swallowed. Upon contact, flush skin or eyes with water. If swallowed, seek immediate medical
attention.
cAUtIoN
Never use automotive anti-freeze in place of propylene glycol. Antifreeze contains corrosion
inhibitors that will damage the torch coolant system.
Always use purified water in the coolant mixture in order to prevent damage to the pump and
corrosion in the torch coolant system.
Defi nitions
Ambient temperature – The temperature of the room in which the chiller is being used.
Premixed coolant for standard operating temperatures
Use Hypertherm premixed coolant (028872) when operating in an ambient temperature range of -12° C to 40° C
(10° F to 104° F). Refer to the custom coolant mix recommendations, if temperatures during operation are ever outside
of this range.
Hypertherm premixed coolant consists of 69.8% water, 30% propylene glycol, and 0.2% benzotriazole.
10/16/08
Summary of Contents for HyPerformance HPR400XD
Page 1: ...HyPerformance Plasma HPR400XD Auto gas Instruction manual 806160 Revision 4 ...
Page 26: ...Specifications 2 2 HPR400XD Auto Gas 806160 ...
Page 48: ...Installation 3 10 HPR400XD Auto Gas 806160 ...
Page 53: ...Installation HPR400XD Auto Gas 806160 3 15 Horizontal RHF mounting Vertical RHF mounting ...
Page 57: ...Installation HPR400XD Auto Gas 806160 3 19 This page is blank intentionally ...
Page 65: ...Installation HPR400XD Auto Gas 806160 3 27 7 8 8 7 ...
Page 100: ...Installation 3 62 HPR400XD Auto Gas 806160 ...
Page 107: ...Operation HPR400XD Auto Gas 806160 4 7 Diagnostic screen ...
Page 108: ...Operation 4 8 HPR400XD Auto Gas 806160 Test screen ...
Page 109: ...Operation HPR400XD Auto Gas 806160 4 9 Cut chart screen ...
Page 197: ...Operation HPR400XD Auto Gas 806160 4 97 ...
Page 287: ...7 4 HPR400XD Auto Gas 806160 Discrete output functionality ...
Page 347: ...Appendix B CNC Interface Protocol b 28 HPR400XD Auto Gas 806160 ...
Page 355: ...4 HPR400XD Auto Gas 806160 ...