Maintenance
HPR400XD Auto Gas –
806160
5-61
torch lead test
1. Turn OFF all power to the system.
2. Locate the start-circuit assembly.
H8
WORK
H9
NOZZLE
H8
WORK
H9
NOZZLE
+
–
D1
D2
3. Install a temporary jumper wire
between H8 (work) and H9
(nozzle) on the start circuit
PCB1.
4. Locate the pilot arc relay (CR1) and remove the dust cover. Have a second person close the contact.
5. Measure the ohm value between the nozzle and the plate. The reading should be less than 3 ohms. A measurement
of greater than 3 ohms indicates a faulty connection between the torch and ignition console or between the ignition
console and the power supply.
6. Verify that the pilot arc wire on the torch lead is not damaged. If it is damaged replace the lead. If it is not damaged,
replace the torch head.
wARNINg
SHock HAzARD
Always use caution when servicing a power supply when plugged in and the covers are removed.
Dangerous voltages exist within the power supply which could cause injury or death.
Summary of Contents for HyPerformance HPR400XD
Page 1: ...HyPerformance Plasma HPR400XD Auto gas Instruction manual 806160 Revision 4 ...
Page 26: ...Specifications 2 2 HPR400XD Auto Gas 806160 ...
Page 48: ...Installation 3 10 HPR400XD Auto Gas 806160 ...
Page 53: ...Installation HPR400XD Auto Gas 806160 3 15 Horizontal RHF mounting Vertical RHF mounting ...
Page 57: ...Installation HPR400XD Auto Gas 806160 3 19 This page is blank intentionally ...
Page 65: ...Installation HPR400XD Auto Gas 806160 3 27 7 8 8 7 ...
Page 100: ...Installation 3 62 HPR400XD Auto Gas 806160 ...
Page 107: ...Operation HPR400XD Auto Gas 806160 4 7 Diagnostic screen ...
Page 108: ...Operation 4 8 HPR400XD Auto Gas 806160 Test screen ...
Page 109: ...Operation HPR400XD Auto Gas 806160 4 9 Cut chart screen ...
Page 197: ...Operation HPR400XD Auto Gas 806160 4 97 ...
Page 287: ...7 4 HPR400XD Auto Gas 806160 Discrete output functionality ...
Page 347: ...Appendix B CNC Interface Protocol b 28 HPR400XD Auto Gas 806160 ...
Page 355: ...4 HPR400XD Auto Gas 806160 ...