Appendix B – CnC interfACe protoCol
b-22
HPR400XD Auto Gas –
806160
ID
Name
Description
054
HIGH SHIELD GAS PRESSURE Gas pressure is over upper limit of 7.58 bar (110 psi).
055
MV 1 INLET PRESSURE
Motor valve 1 inlet pressure is less than 3.45 bar (50 psi) or
greater than 9.65 bar (140 psi).
056
MV 2 INLET PRESSURE
Motor valve 2 inlet pressure is less than 3.45 bar (50 psi) or
greater than 9.65 bar (140 psi).
057
CUT GAS 1 PRESSURE
In the selection console, cut gas 1 outlet pressure is less than
3.45 bar (50 psi) or greater than 9.65 bar (140 psi).
058
CUT GAS 2 PRESSURE
In the selection console, if cut gas 2 outlet pressure is less than
3.45 bar (50 psi) for non-mixing, or less than 1.38 bar (20 psi)
when mixing or greater than 9.65 bar (140 psi) for non-mixing
and mixing.
060
LOW COOLANT FLOW
Coolant flow is less than the required 2.3 lpm (0.6 gpm).
061
NO PLASMA GAS TYPE
Plasma gas has not been selected.
062
NO SHIELD GAS TYPE
Shield gas has not been selected, or system is in test mode.
065 Primary
265 Secondary CHOPPER1 OVERTEMP
Chopper #1 overheated.
066 Primary
266 Secondary CHOPPER2 OVERTEMP
Chopper #2 overheated.
067 Primary
267 Secondary MAGNETICS OVERTEMP
Transformer has overheated.
071
COOLANT OVERTEMP
Torch coolant has overheated.
072
AUTOMATIC GAS CONTROL
BOARD OVERTEMP
Control board has exceeded 90° C (194° F).
073 Primary
273 Secondary CHOPPER3 OVERTEMP
Chopper #3 overheated
074 Primary
274 Secondary CHOPPER4 OVERTEMP
Chopper #4 overheated
075 Primary
275 Secondary
CURRENT TOO LOW ON LEM
#3
A current less than 10 amps has been detected by current
sensor 3.
076 Primary
276 Secondary
CURRENT TOO LOW ON LEM
#4
A current less than 10 amps has been detected by current
sensor 4.
093
NO COOLANT FLOW
Coolant flow is less than 0.6 gpm.
095
CURRENT TOO HIGH ON LEM
#4
Current has exceeded 35 amps during the chopper test
099 Primary
299 Secondary CHOPPER1 OVERTEMP AT INIT Chopper #1 is indicating overtemp during power-up.
100 Primary
300 Secondary CHOPPER2 OVERTEMP AT INIT Chopper #2 is indicating overtemp during power-up.
101 Primary
301 Secondary
MAGNETICS OVERTEMP AT
INIT
Transformer is indicating overtemp during power-up.
102 Primary
302 Secondary OUTPUT CURRENT AT INIT
Chopper current signal is active on power-up.
103 Primary
303 Secondary
CURRENT TOO HIGH ON LEM
#1
A current greater than 35 amps has been detected by current
sensor 1.
104 Primary
304 Secondary
CURRENT TOO HIGH ON LEM
#2
A current greater than 35 amps has been detected by current
sensor 2.
105 Primary
305 Secondary
CURRENT TOO LOW ON LEM
#1
A current less than 10 amps has been detected by current
sensor 1.
Summary of Contents for HyPerformance HPR400XD
Page 1: ...HyPerformance Plasma HPR400XD Auto gas Instruction manual 806160 Revision 4 ...
Page 26: ...Specifications 2 2 HPR400XD Auto Gas 806160 ...
Page 48: ...Installation 3 10 HPR400XD Auto Gas 806160 ...
Page 53: ...Installation HPR400XD Auto Gas 806160 3 15 Horizontal RHF mounting Vertical RHF mounting ...
Page 57: ...Installation HPR400XD Auto Gas 806160 3 19 This page is blank intentionally ...
Page 65: ...Installation HPR400XD Auto Gas 806160 3 27 7 8 8 7 ...
Page 100: ...Installation 3 62 HPR400XD Auto Gas 806160 ...
Page 107: ...Operation HPR400XD Auto Gas 806160 4 7 Diagnostic screen ...
Page 108: ...Operation 4 8 HPR400XD Auto Gas 806160 Test screen ...
Page 109: ...Operation HPR400XD Auto Gas 806160 4 9 Cut chart screen ...
Page 197: ...Operation HPR400XD Auto Gas 806160 4 97 ...
Page 287: ...7 4 HPR400XD Auto Gas 806160 Discrete output functionality ...
Page 347: ...Appendix B CNC Interface Protocol b 28 HPR400XD Auto Gas 806160 ...
Page 355: ...4 HPR400XD Auto Gas 806160 ...