ZT-5400 Powertrain
19
51
65 66
67
52
53
54
55
57
56
figure 10, Control arm
COnTrOl arm assembly
Refer to Figure 10
disassembly
1 . Remove all items previously discussed in
their recommended order .
2 . Remove the Torx head screw (56) and dis-
card .
3 . Remove the nut (57) and the washer (55) .
4 . Remove the control arm (54) .
5 . Remove the plastic washer (53) and the
stud (52) .
6 . Remove the stop plate (65) .
NOTE:
Only remove the lip seal (51) and stop
plate (65) if damaged or worn, or if
doing a complete disassembly. Mark
the orientation of the stop plate before
removal.
Inspection
1 . Inspect all parts for excessive wear or dam-
age . Replace if necessary .
assembly
1 . Reassemble all parts in the reverse order
of disassembly .
2 . When tightening the fasteners, refer to the
table on page 15 for the required torque
values .
3 . Install new Torx head screw (56) and lip seal
(51) from seal kit .
NOTE:
As a general rule, use the low end of
the torque specification on fasteners
when reassembling the unit.
www.mymowerparts.com
Hydro Gear Parts or New Units Call 606-678-9623 or 606-561-4983