Connecting the SMU
SensorMonitoring Unit - SMU
en(us)
Page 29 / 100
BeWa SMU1200 3854281 V2.0x en(us) 2013-08-20
2013-08-20
Interface D - AS1000 OUT
Here you can tap into the output signals of a connected AS1000 for further
utilization.
The bus signals such as RS485 and HSI are not transferred by
the sensor.
The SMU has its own HSI interface (G).
Our accessories list includes connection cables of different lengths with one
connector and the following configuration:
Pin
Color code Connection to AS1000
2
White
"Saturation"
analog output
4 … 20 mA 0 … 100 %
3
blue
GND
4
black
"Temperature" analog
output
4 … 20 mA -25 … 100°C
Please see the sensor documentation for more detailed information.
5-pin connection cable, open cable end:
The color coding of the connection cable is valid only for cables
from the scope of delivery and for original replacement parts.