Evaluating stored records
SensorMonitoring Unit - SMU
en(us)
Page 79 / 100
BeWa SMU1200 3854281 V2.0x en(us) 2013-08-20
2013-08-20
Evaluating stored records
The measurement records read out of the SMU and stored on the USB
memory stick are defined as follows:
Directories to store the records
Memory setting FILL
These saving process takes place according to measurement points if the
setting FILL has been selected in the PowerUp menu under the setting
REC.MOD. (see page 55)
If measurements are to be stored under a measurement point MNPT, the
SMU will automatically produce a directory for this measurement point and
will put the record there.
New measurement files are created in FILL mode, as soon as:
The SMU is switched off and then switched back on.
The USB memory stick is plugged into the USB port for data transfer.
In the Measuring menu under RECORD, the menu item STP.STA for
creation of a new measurement file is activated with the
o.k.
button.
Memory setting RING
This saving process takes place in the directory for the measurement point
MNPT00 if the setting RING has been selected in the PowerUp menu under
the REC.MOD setting. (for more information, see page 55).
If an data set already in existence is recognized by the SMU, the file ending
is counted up by 1.