HYDAC FILTER SYSTEMS GMBH
Operation | 6
BeWa OF5 CM 3580053c en-us print
49 / 80
2.
Connect the suction hose to the oil tank/container and fit
the suction hose in it and also secure it against falling
out.
3.
Connect the pressure hose to the oil tank/container and
fit the pressure hose in it and also secure it against fall-
ing out.
4.
Connect the filter unit to the voltage source.
5.
Switch the filter unit on at the main switch.
6.
Continuously monitor the fluid level in the oil tank/con-
tainer to be filled during circulation pumping.
7.
If the required filling quantity is reached, switch the filter
unit off at the main switch.
8.
Release the pressure hose at the quick coupling, see
Dismounting/mounting the quick coupling.
9.
Empty the contents of the pressure hose into the oil
tank/container.
10.
Empty the contents of the suction hose into the oil tank/
container.
11.
Secure the pressure hose at the quick coupling, see Dis-
mounting/mounting the quick coupling.