MCS 1000 Series
Error analysis / remedy
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 57 / 76
BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc
2012-06-15
Switching l
ogic
Signal value at
switching output
Step 1
Step 2 / 3
Status
Remedy
High
ON
ON
The MCS has not
detected any particle
-
active low
Low
ON
ON
Error on the MCS
Contact HYDAC
Low
ON
ON
The MCS has not
detected any particle
-
active high
High
ON
ON
Error on the MCS
Contact HYDAC
ON
OFF
Error in measurement
voltage
Reestablish the
measurement voltage.
OFF
ON
The MCS is switched
off; error in operation
voltage
Reestablish the
operation voltage.
OFF
OFF
The MCS is switched
off; error in operation
voltage / measurement
voltage
Reestablish the
operation and
measurement voltage.