MCS 1000 Series
Model Code
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 67 / 76
BeWa MCS1000 3435427f V130 en-us 2012-06-15.doc
2012-06-15
Model Code
MCS
1 5 1 0 - 5 - 0 / 000
Product
MCS = MetallicContamination Sensor
Series
1 =
1000
Series
Contamination / sensor cross-section
3
= Particle >70 µm / 1/4"
4
= Particle >100 µm / 1/2"
5
= Particle >200 µm / 1“
Signal technology
1
- 2x Switching o HSI/RS485 (HSI protocol)
7
- 2x Switching outputs / RS485 Ethernet (HSI TCP/IP
protocol)
Fluids
0
= Mineral and synthetic oils
(particularly used in wind power industry)
Mechanical connection
1
= Flange connection, SAE 1/2" according to ISO 6162-1
(only for MCS13xx)
2
= Flange connection, SAE 3/4" according to ISO 6162-1
(only for MCS14xx)
5
= Flange connection, SAE 4" according to ISO 6162-1
(only for MCS15xx)
Electrical connection
0
= Male connection M 12x1, 8 pole
1
= Male connection M 12x1, 8 pole and Ethernet M 12x1, 4 pole, D
coded acc. IEC61076-2-101
Modification number
000 = Standard