Errors and troubleshooting
LVU-CD-10
en(us)
Page 42 / 52
BeWa LVU-CD-10 Eco 4067271 en-us 2016-01-08.doc
2016-01-08
Error
Cause(s)
Remedy
The fluid is heavily
contaminated.
The contamination
retention capacity
of the filter element
has been reached.
Replace the filter element.
The filter element is
clogged.
The optical
clogging indicator
reads
≥
2.5 bar.
The suction line at
the inlet is
generating too
much loss of
pressure.
Ensure that the pressure at the
inlet is within the permitted
range.
Leakage on the unit
/ filter housing
Empty the collecting pan and
eliminate the leak on the unit.
Wrong, missing, or
defective sealing
ring.
Check the sealing ring on the
filter element. Replace it if
necessary.
The filter element is
insufficiently
tightened.
Tighten the filter housing
somewhat by hand.
Collecting pan too
full.
The water drain
plug (4.1) is not
closed.
Close the water drain plug (4.1).