Unit setup/connection
LVU-CD-10
en(us)
Page 25 / 52
BeWa LVU-CD-10 Eco 4067271 en-us 2016-01-08.doc
2016-01-08
Connecting the suction port (IN)
For the suction port connection, use a flexible hose that is resistant to
negative pressure. Avoid constrictions in the connecting lines, as they
compromise suction performance and increase the risk of cavitation.
NOTICE
Overpressure at the suction port connection
The unit will be damaged
►
The pressure on the suction port connection IN must not be more
than -0.4 to 0.2 bar.
Connecting the pressure port (OUT)
Make sure that the nominal width of the pressure line corresponds to the
connector thread of the filter housing.
Install the return line below the fluid level to prevent air from entering the fluid
in the tank
NOTICE
Excess pressure at the pressure port connection
The unit will be damaged
►
The pressure on the suction port connection OUT must not be more
than a maximum of 3 bar.