Errors and troubleshooting
LVU-CD-10
en(us)
Page 40 / 52
BeWa LVU-CD-10 Eco 4067271 en-us 2016-01-08.doc
2016-01-08
Errors and troubleshooting
The following errors could have different causes. The following provides
information on which remedial measures are required.
Error
Cause(s)
Remedy
No supply voltage
available.
Check the feed-line and plug.
Unit is not pumping
The main switch is
switched off but the
power supply is on
Check the main switch.
The is no power at
the electric motor.
The power outlet used is free of
voltage.
The mains connector is not
plugged in. Plug in the power
plug.
Inspect the unit supply line for
damage. If the unit supply line is
defective, replace it immediately.
The mains voltage
or frequency do not
correspond to the
specifications on
the unit.
Use a unit that is suitable for the
mains voltage.
The unit is switched
off at the main
switch.
Switch on the unit at the main
switch.
Electric motor /
pump is not running
The electric motor /
pump is defective.
Contact HYDAC.