Adjusting the counter balance valve
CMP1000
en(us)
Page 32 / 44
MoWa CMP 3528418d en-us 2015-01-06.doc
2015-01-06
from the viscosity and the
hydraulic resistance.
4.
Unscrew the head-nut from the
counter balance valve (1).
5.
Release the lock nut on the
counter balance valve (1).
6.
Set the pressure for a maximum
operating medium viscosity to 25
... 35 bar by using a size 4 Allen
wrench to rotate the set screw on
the counter balance valve (1).
Note that it is recommended that
at least10 bar is added to the
value measured in step 3.