Model Code
CMP1000
en(us)
Page 41 / 44
MoWa CMP 3528418d en-us 2015-01-06.doc
2015-01-06
Model Code
CMP
1
2
2
0 - 2 - 1
N/AB/N60/AB6
0
AS
Type
CM
P
= ConditionMonitoring
Package
Version
1
= 4 particle size channels
Contamination code
2
= ISO4406:1999, SAE AS
4059(D) /
>4 µm
(c)
>6 µm
(c)
, 14 µm
(c)
>21
µm
(c)
3
= ISO4406:1987, NAS1638 /
>2 µm >5 µm >15 µm > 25 µm
ISO4406:1999, SAE AS
4059(D) /
>4 µm
(c)
>6 µm
(c)
, 14 µm
(c)
>21 µm
(c),
can be switched
Options
1 =
without
display
2 =
with
display
Fluids
0
= based on mineral oil
Hydraulic Version
2
= Pump, inlet pressure stability up to a
maximum of 80 bar,
(oil leakage pipe connected internally with
return port connection)
4
= Pump, inlet pressure-stable, up to a
maximum of 80 bar,
without oil leakage pipe
Electrical Outlet
1
= 4 … 20 mA analog outlet
2
= 0 … 10 V analog outlet
Supply voltage
W/N/X60/O60 =
230 V, 50 Hz, 3 Ph / 265 V 60 Hz, 3 Ph
400 V, 50 Hz, 3 Ph / 460 V 60 Hz, 3 Ph
N/AB/N60/AB
60
=
400 V, 50 Hz, 3 Ph / 400 V 60 Hz, 3 Ph
690 V, 50 Hz, 3 Ph / 690 V 60 Hz, 3 Ph
Other voltages on request
Supplementary sensors
AS
= with AquaSensor AS1000