6. Change Temperature Setting and Thermal Cut-out Reset
•
It is important to isolate the product from the mains power supply by unplugging
but is not necessary to isolate the water supply.
•
Open the boiling side of the tap until water runs cold.
•
The Zen Spa is factory set at 100°C. The temperature of dispensed boiling water can
be changed on the tank PCB. Switch between ‘LO’ 98°C or ‘HI’ 100°C.
•
See Diagram 5 and 6 overleaf.
•
For the 3L model unscrew the 2 crosshead screws that retain the boiling tank lid.
•
Lift the lid slightly from the back before removing by sliding it forward to free it
from the retaining lug at the front.
•
For the 6L model unscrew the 2 crosshead screws that retain the back section and
fold down.
•
To change the temperature locate the temperature setting switch; slide to HI for
100°C / LO for 98°C setting as appropriate.
•
To reset the thermal cut-out locate and press the reset button. For the 3L model
this is on the PC board. For the 6L model it is on the top of the boiling tank.
•
For the 3L model replace the lid by first lining up the lug at the front before gently
angling the back into place. Replace the two retaining screws and when the lid is
secured in place re-connect the electrical supply.
•
For the 6L model lift and replace the back section and replace two retaining screws.
When the lid is secured in place re-connect the electrical supply.