9. Draining
•
Do not connect to electricity supply without re-filling the tank, checking for leaks
and purging any air out of the system.
•
Unplug the unit from the electricity mains.
•
Run the boiling tap until it is dispensing cold water.
•
Unplug the black lead tap connector (3.5 mm jack) from the back of the heater.
•
Turn off water supply. Disconnect the water supply to the tank and tap. Lift the tank
to the sink, turn upside down and drain all the water from the tank.
•
When re-installing follow the original installation instructions.
10. Descaling the Tank
A service cartridge can be used to descale the boiling water tank. These are available
from Hyco, please contact our service department for further information.
11. Specification
Supply
230V ~ 50Hz
Power 3/ 6L model
1.55/ 2.84 kW
Tank capacity 3/ 6L model
3/ 6 litres
Max water pressure
0.42 MPa (4.2 bar)*
Min water pressure
0.1MPa (1 bar)
Max tank pressure
0.6 MPa (6 bar)
Ambient operating temperature
5 – 35°C
Approvals
CE, WRAS (98°C only)
* If pressure is above 0.42 MPa (4.2 bar) then a pressure reducing valve is required.
Product Description
SPA3L
Zen Spa 100°C Tap 3L Boiling and Ambient
SPA6L
Zen Spa 100°C Tap 6L Boiling and Ambient
SPA3LUC1
Zen Spa 100°C Tap 3L Boiling and 20L/ h Chilled
SPA6LUC1
Zen Spa 100°C Tap 6L Boiling and 20L/ h Chilled