13. Guarantee

This product is covered by a standard parts or replacement warranty for a period of 2 

years from the date of purchase. 

If there is a manufacturing defect within the warranty period we will send spare parts, 

repair and return the unit or, at our discretion, supply a replacement product. Incorrect 

installation, frost damage, the consequences of limescale deposits or failure to follow 

correct operating and maintenance instructions are excluded. Consequential costs such 

as labour charges or damage to fittings and surroundings are expressly excluded. 

14. Contact Us

If you experience a problem with this product you should first contact our service 

department on 01924 225 200 before taking any further action. Experience has shown 

that issues can often be resolved without the need to return or uninstall the product.

Hyco Manufacturing Ltd

Normandy Court

Express Way

Castleford, WF10 5NR

T     01924 225 200

F     01924 225 210

E     [email protected]

hyco.co.uk

INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE 

WITH THE EUROPEAN DIRECTIVE 2012/19/EU.

At the end of its working life this equipment must not be disposed of as household 

waste. It must be taken to a local authority waste collection centre or to a dealer 

providing this service. Disposing of electrical and electronic equipment separately 

enables its components to be recovered and recycled to obtain significant savings 

in energy and resources. In order to underline the duty to dispose of this equipment 

separately, the product is marked with a crossed out dustbin.

24

Summary of Contents for Zen Spa Series

Page 1: ...Product Instruction Manual Zen Spa 2 in 1 Boiling and Chilled Tap SPA3L SPA6L SPA3LUC1 SPA6LUC1 v19 12 1 ...

Page 2: ...itial high quality scale filter for the inlet to the boiling tank and a cold drinking water filter Two temperature settings 100 C and 98 C Can be installed over a sink or with a stylish Zen Font Designed and assembled in the UK Always switch off the mains electricity before commencing installation Only connect the unit to a single phase supply as specified on the rating plate Ensure tank is full o...

Page 3: ...ove scale deposits see maintenance section Water may drip from the pressure relief valve this must be piped to drain as per local relevant regulations This appliance can be used by children aged 12 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the applianc...

Page 4: ...alve Manifold Cold drinking water filter Hose manifold to exp vessel Hose manifold to tank fixing bracket and metal band Scale filter Hose tank to tap Zen tank Zen Spa tap Expansion vessel For Zen Spa with chiller UC1 models chiller sent separately 4 ...

Page 5: ...1 2 female to 3 8 PF 2 x Black rubber washer 1 x Large and 3 x small white washer 1 5 m x 1 4 and 3 8 tubing 6 x Large locking collar and 5 x small 2 x 1 2 BSP to 15mm 1 x 3 way 3 8 to 1 4 PF 1 4 x 1 4 PF 5 ...

Page 6: ...is factory set at 100 C The temperature can be switched down to 98 C should this be desired Please see Section 6 for further instructions White washers are to facilitate water connections on hoses labelled tank to tap and manifold to tank Black washers are to facilitate water connections on hose labelled manifold to exp vessel Ensure that all hose connections are tightened using a suitable spanner...

Page 7: ...Diagram 1 7 ...

Page 8: ...a standard sink If installing in a Zen Font with Drain use the template supplied with the Zen Font to establish tap hole position The tap can be installed onto sink countertop up to 50 mm thick Place tap into hole ensure the black o ring is above the worktop See Diagram 2 Place the steel washer onto the threaded section of the tap under worktop sink Lastly the brass locking nut will screw onto the...

Page 9: ...Diagram 2 9 ...

Page 10: ...installing a chiller please see Diagram 4 in Section 2 Note the boiling tank must be located as close to the tap as practicable as it is not possible to extend hoses provided Attach M BSP to 15 mm compression fitting to offtake 1 see Diagram 3 of the manifold and tighten with spanner Connect to desired length of copper pipe then connect to relief valve This is a safety device which must be fitted ...

Page 11: ...sel bracket to the required surface using screw pack Attach the other end of hose labelled manifold to exp vessel to expansion vessel using 1 black washer Secure expansion vessel in place against bracket using metal band Step 4 Connect Boiling Tank and Spa Tap From offtake 2 of the manifold attach hose labelled manifold to tank using 1 large white washer Connect remaining end to tank inlet using 1...

Page 12: ...ow is followed To do so first remove filter cartridge Now grip bracket in one hand and the top t section with the other turn 90 anti clockwise to release Rotate 180 and reinsert t section turning 90 in whichever direction is required depending on installation to secure Do not locate the filter above an electrical socket or other electrical device Secure the bracket to the wall using the fixings su...

Page 13: ...trical socket or other electrical device Remove drinking water filter cartridge from the filter head secure the bracket to the wall using the fixings supplied Replace the filter cartridge into filter head Use suitable length of tubing to connect remaining outlet of t piece to drinking water filter inlet marked IN Use suitable length of tubing to connect drinking water filter outlet marked OUT to c...

Page 14: ...length of tubing to connect from remaining outlet of t piece to drinking water filter inlet marked IN Use a suitable length of tubing to connect drinking water filter outlet marked OUT one of the identical connectors and a black washer provided with the chiller to facilitate connection to WATER IN Use remaining identical connector and a black washer provided with the chiller to facilitate connecti...

Page 15: ...Diagram 4 15 ...

Page 16: ...d water Test the pressure relief valve by twisting the red cap until water flows from the valve If it is discharging whilst the heater is turned off this is a sign that the incoming pressure exceeds the 4 2 bar rating of the pressure relief valve A pressure reducing valve is required not supplied When the air is purged the tap is closed and the system is fully pressurised inspect all connections f...

Page 17: ...t begins flashing red this indicates a fault has been detected The unit should be isolated from the power supply and the water supply shut off before contacting Hyco for further advice Status Ring Summary Red Water is heating Green Water is up to temperature ready to use Fading in out green Predicted non use period sleep mode Flashing red Fault detected 5 Operation This appliance can be used by ch...

Page 18: ...p towards the blue marker Releasing the safety lock is not required to dispense cold drinking water Operating the Tank Once the boiling tank is installed following the correct installation instructions there should be no further operation required In the event you wish to switch between 100 C and 98 C please see Section 6 The factory setting is 100 C Please note the Zen tank is a storage type heat...

Page 19: ...it from the retaining lug at the front For the 6L model unscrew the 2 crosshead screws that retain the back section and fold down To change the temperature locate the temperature setting switch slide to HI for 100 C LO for 98 C setting as appropriate To reset the thermal cut out locate and press the reset button For the 3L model this is on the PC board For the 6L model it is on the top of the boil...

Page 20: ...3L Model PC Board Diagram 5 6L Model PC Board Diagram 6 20 ...

Page 21: ... damage is discovered discontinue use isolate the water supply and drain down immediately Contact Hyco The relief valve must be regularly tested To do this twist the red cap until water flows from the valve If water does not flow it must be replaced The tap and water tank can be cleaned with a lint free damp cloth Do not use any abrasive or caustic cleaning products this will damage the surface of...

Page 22: ...e Tank A service cartridge can be used to descale the boiling water tank These are available from Hyco please contact our service department for further information 11 Specification Supply 230V 50Hz Power 3 6L model 1 55 2 84 kW Tank capacity 3 6L model 3 6 litres Max water pressure 0 42 MPa 4 2 bar Min water pressure 0 1MPa 1 bar Max tank pressure 0 6 MPa 6 bar Ambient operating temperature 5 35 ...

Page 23: ...Contact Hyco Low flow from the cold side of the tap Drinking water filter needs changing Replace drinking water filter cartridge See Section 8 Low flow from the boiling side of the tap Scale filter needs changing Replace scale filter cartridge See Section 8 Low flow from the boiling side of the tap Scale build up in tank Descale tank See section 10 Low flow from the tap Aerator needs cleaning Unsc...

Page 24: ...n 01924 225 200 before taking any further action Experience has shown that issues can often be resolved without the need to return or uninstall the product Hyco Manufacturing Ltd Normandy Court Express Way Castleford WF10 5NR T 01924 225 200 F 01924 225 210 E sales hyco co uk hyco co uk INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH THE EUROPEAN DIRECTIVE 2012 19 EU At the end ...

Page 25: ......

Reviews: