The tank must be sited vertically and on a flat level surface.
The supplied scale filter must be fitted and changed at least every 6 months,
otherwise the lifespan of the product could be seriously reduced and the
warranty may be void.
The supplied drinking water filter must be changed at least every 6 months.
A pressure reducing valve is required if the mains pressure is above 0.42 MPa (4.2
bar).
The Zen Spa is factory set at 100°C. The temperature can be switched down to
98°C should this be desired. Please see Section 6 for further instructions.
White washers are to facilitate water connections on hoses labelled ‘‘tank to tap’
and ‘manifold to tank’.
Black washers are to facilitate water connections on hose labelled ‘manifold to
exp vessel’.
Ensure that all hose connections are tightened using a suitable spanner.
Ensure that the tank, power socket, service valve and installation kit (manifold,
relief valve and expansion vessel) are positioned to allow future maintenance.
1. Installation
Important Installation Information