6-2
S
eRvice
P/N 0518258_D
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • WWW.HUSSMANN.COM
P/N 0518258_C
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • www.hussmann.com
6-2
S
ERVICE
REPLACING FLUORESCENT LAMPS
Fluorescent lamps are furnished with moisture
resistant lamp holders, shields and end caps.
Whenever a fluorescent lamp is replaced, be
certain to reinstall the lamp shields and end
caps.
The rail lamp switch is located on the rail.
Inspect all lamp sockets and plug–receptacle
connections for signs of arcing. Replace any
component that shows signs of arcing.
Make sure all unused receptacles have their
close-off covers securely attached.
REPLACING LAMP HOLDERS AND
END CAPS
The lamp holder is designed to snap into the
sheet metal of the case. The lamp holder has a
locking ‘nub’ which fits inside the groove of
specially designed end caps.
IMPORTANT!
Always replace lamp holders and end caps with
Hussmann lamp holders and end caps.
Use of non-Hussmann parts may result in
poor electrical contact and short lamp life.
Groove
Nub
Hussmann
End-Cap
Hussmann
Lamp Holder
Fluorescent
Lamp
Plastic Shield
End Cap