P/N 0518258_D
6-3
Produce & Bakery
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Medium Temperature
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
P/N 0518258_C
6-3
REPLACING ELECTRONIC BALLASTS
Rail Lamp Ballast
The rail lamp ballast is located in the wireway,
behind the lower front panel at the left-hand
end of the merchandiser.
NOTE:
The switch
for the rail lamp is separate from the canopy
and shelf lighting. The rail lamp switch is
located on the rail.
To gain access:
1.
D
ISCONNECT THE ELECTRICAL POWER TO
THE
MERCHANDISER
.
2. Remove the lower front panel by lifting it
up and out.
3. Remove screws attaching the wireway cover,
then remove cover.
4. Service or replace ballast as required.
Reassemble items as they were originally
installed.
5. Reconnect the electrical power.
REPLACING DAMAGED
DRAIN FITTING
The following procedure is for the field repair
of a broken drain fitting.
1. Use a drill with a 2 in. (51 mm) hole saw to
drill out the bottom of the drain fitting. Be
sure to drill completely through fitting and
bottom liner.
2. Apply an ABS and PVC compatible
primer-sealer to outside of PVC coupling
and inside of drain. Insert coupling into
drain fitting.
3. Install a PVC adapter on the drip trap.
Apply primer-sealer to a stub piece of PVC
pipe and insert between coupling and
adapter.
Lower
Front Panel
Ballast located
inside wireway
Drain Fitting
Viewed from Inside Merchandiser
Foam Bottom
Assembly
Modified
Drain Fitting
Drip
Trap
Stub
Pipe
PVC Adapter
1-1/2 x 1-1/4 in.
(38 x 32 mm)
(obtained at
local building
supply store)
PVC Coupling
slip fit, 2 in. OD (51mm)
1-1/4 in. ID (32 mm)
(obtained at local
building supply store)