Item

Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES

AND

T

HERMOSTATS

A.

4W

Standard Fan Assembly

(1)

0392457

Fan Motor,  Evaporator
(MO.4410101)

0464847

Fan Blade (FB.4780649)

4W

Energy Efficient Fan Assembly

(1)

0477653

Fan Motor,  Evaporator
(MO.4410544)

0464847

Fan Blade (FB.4780649)

B.

Optional Adjustable Refrigeration Thermostat (2)

C.

0398557

Defrost Termination Thermostat

(3)

(Electric Defrost only)
(CT.4440611)

D.

0481370

Heater Switch

(4)

(Koolgas Defrost only)
(CT.4440738)

Item

Part #

Description

Wiring Item #

H

EATERS

E.

208V Evaporator Defrost Heaters

(5)

0462159

8 ft case (HE.4850603)

0444058

12 ft case (HE.4850571)

F.

208V Drip Pan Defrost Heaters, Electric 

(6)

0462160

8 ft case (HE.4850636)

0444296

12 ft case (HE.4850572)

120V Drip Pan Defrost Heaters, Koolgas 

(7)

0465907

8 ft case (HE.4850622)

0465908

12 ft case (HE.4850623)

G.

Nosing Anti-sweat Heaters 

(8)

0495007

8 ft case (HE.4850685)

0495008

12 ft case (HE.4850686)

FN

Technical Data Sheet

P/N 0465898_C

NSF

®

Certified

March  2008

©2008 HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM

Note:  Revision C updates the Heater Switch part number on Page 1 and adds capacity and weight (

Page 5

).

Summary of Contents for FN

Page 1: ...Termination Thermostat 3 Electric Defrost only CT 4440611 D 0481370 Heater Switch 4 Koolgas Defrost only CT 4440738 Item Part Description Wiring Item HEATERS E 208V Evaporator Defrost Heaters 5 046215...

Page 2: ...1 5 8 802 31 5 8 802 Distance between edges of external legs and center legs 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA 43 7 8 1114 Distance between front legs and splashguard 3...

Page 3: ...oor Unit Only Pressure Defrost Termination Not Recommended Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb 8 ft 2 0 12 ft 3 0 This is an average for all refrigerant...

Page 4: ...16 230V 60Hz Energy Efficient 0 12 0 12 16 16 Anti sweat Heaters on fan circuit 120V 50 60Hz Standard 0 67 1 00 80 120 230V 50 60Hz Export 0 35 0 52 80 120 Minimum Circuit Ampacity 120V 60Hz Standard...

Page 5: ...t Ft 3 55 ft3 ft 0 33 m3 m ARI Total Display Area 3 Sq Ft Ft 2 78 ft2 ft 0 85 m2 m Shelf Area 4 Sq Ft Ft 2 79 ft2 ft 0 85 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3...

Page 6: ...Red 5 Defrost Termination Thermostat Dark Blue To Condensing Unit 3 Light Blue 2 To Condensing Unit Refrigeration Thermostat Optional 1 BROWN BAND Fans BROWN BAND Nosing Anti sweat Heater 120V POWER...

Page 7: ...W HUSSMANN COM Gas Defrost Optional WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers 7 4 120V Drip Pan Heater Koolgas On...

Reviews: