background image

REFRIGERATION DATA

Note: 

This data is based on store temperature and

humidity that does not exceed 75

°

F and 55% R.H. 

M

ED

FF

IC

Discharge Air (°F)

+24

–12

–22

Evaporator(°F)

+19

–20

–30

Unit Sizing (°F)

+17

–23

–33

Btu/hr/ft

M

ED

FF

IC

Parallel

280

390

400

Conventional

290

405

415

DEFROST DATA

M

ED

FF

IC

Frequency 

(hr)

24

24

24

Defrost Water 

(lb/ft/day)

0.8

0.75

0.6

(± 15% 

based on case configuration and product

loading).

E

LECTRIC

M

ED

FF

IC

Temp Term (°F)

48

48

48

Failsafe

(minutes)

60

60

60

G

AS

Duration (minutes)  

NA

15

18

O

FFTIME

Not Recommended 

Standard Defrost Thermostat 

Close on rise: close 48°F  —  open 33°F 

CONVENTIONAL CONTROLS

Low Pressure Backup Control — CI/CO 

*

M

ED

+12°F / +2°F

FF

–17°F / –29°F

IC

–27°F / –39°F

Indoor Unit Only, Pressure Defrost Termination

*

Not Recommended

*Use a Temperature Pressure Chart to determine PSIG

conversions.

Estimated Charge (lb)**

8 ft 

2.0

12 ft 

3.0

**This is an average for all refrigerant types. Actual

refrigerant charge may vary by approximately half a

pound.

Length Added to Lineup by Each 

End or Partition (in.)

2

3 of 7

P/N 0465898_C

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

FAN

COIL

Refrigeration 
Outlet

15 

1

/

 

(388)

35 

7

/

8

 

(910)

33 

3

/

8

 (848)

1

/

2

 

(140)

1

/

8

 

(79)

26 

3

/

8

 

(669)

27 

5

/

8

 (701)

19 

7

/

8

 (503)

FN

33 

(839)

34 

3

/

4

 (884)

43 

3

/

8

 (1101)

31 

5

/

8

 (802)

Case-to-Case 
Connection

Impact  

Excel

FN

Low / Medium Temperature 

Narrow Island Display with Solid Walls

Dimensions shown as inches & (mm).

NSF Certification

This merchandiser model is manufactured to meet ANSI/NSF
(National Sanitation Foundation) Standard #7 requirements for
construction, materials & cleanability.

Summary of Contents for FN

Page 1: ...Termination Thermostat 3 Electric Defrost only CT 4440611 D 0481370 Heater Switch 4 Koolgas Defrost only CT 4440738 Item Part Description Wiring Item HEATERS E 208V Evaporator Defrost Heaters 5 046215...

Page 2: ...1 5 8 802 31 5 8 802 Distance between edges of external legs and center legs 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA 43 7 8 1114 Distance between front legs and splashguard 3...

Page 3: ...oor Unit Only Pressure Defrost Termination Not Recommended Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb 8 ft 2 0 12 ft 3 0 This is an average for all refrigerant...

Page 4: ...16 230V 60Hz Energy Efficient 0 12 0 12 16 16 Anti sweat Heaters on fan circuit 120V 50 60Hz Standard 0 67 1 00 80 120 230V 50 60Hz Export 0 35 0 52 80 120 Minimum Circuit Ampacity 120V 60Hz Standard...

Page 5: ...t Ft 3 55 ft3 ft 0 33 m3 m ARI Total Display Area 3 Sq Ft Ft 2 78 ft2 ft 0 85 m2 m Shelf Area 4 Sq Ft Ft 2 79 ft2 ft 0 85 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3...

Page 6: ...Red 5 Defrost Termination Thermostat Dark Blue To Condensing Unit 3 Light Blue 2 To Condensing Unit Refrigeration Thermostat Optional 1 BROWN BAND Fans BROWN BAND Nosing Anti sweat Heater 120V POWER...

Page 7: ...W HUSSMANN COM Gas Defrost Optional WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers 7 4 120V Drip Pan Heater Koolgas On...

Reviews: