REFRIGERATION DATA
Note:
This data is based on store temperature and
humidity that does not exceed 75
°
F and 55% R.H.
M
ED
FF
IC
Discharge Air (°F)
+24
–12
–22
Evaporator(°F)
+19
–20
–30
Unit Sizing (°F)
+17
–23
–33
Btu/hr/ft
M
ED
FF
IC
Parallel
280
390
400
Conventional
290
405
415
DEFROST DATA
M
ED
FF
IC
Frequency
(hr)
24
24
24
Defrost Water
(lb/ft/day)
0.8
0.75
0.6
(± 15%
based on case configuration and product
loading).
E
LECTRIC
M
ED
FF
IC
Temp Term (°F)
48
48
48
Failsafe
(minutes)
60
60
60
G
AS
Duration (minutes)
NA
15
18
O
FFTIME
Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control — CI/CO
*
M
ED
+12°F / +2°F
FF
–17°F / –29°F
IC
–27°F / –39°F
Indoor Unit Only, Pressure Defrost Termination
*
Not Recommended
*Use a Temperature Pressure Chart to determine PSIG
conversions.
Estimated Charge (lb)**
8 ft
2.0
12 ft
3.0
**This is an average for all refrigerant types. Actual
refrigerant charge may vary by approximately half a
pound.
Length Added to Lineup by Each
End or Partition (in.)
2
3 of 7
P/N 0465898_C
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
FAN
COIL
Refrigeration
Outlet
15
1
/
4
(388)
35
7
/
8
(910)
33
3
/
8
(848)
5
1
/
2
(140)
3
1
/
8
(79)
26
3
/
8
(669)
27
5
/
8
(701)
19
7
/
8
(503)
FN
33
(839)
34
3
/
4
(884)
43
3
/
8
(1101)
31
5
/
8
(802)
Case-to-Case
Connection
Impact
Excel
FN
Low / Medium Temperature
Narrow Island Display with Solid Walls
Dimensions shown as inches & (mm).
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF
(National Sanitation Foundation) Standard #7 requirements for
construction, materials & cleanability.