9.25
9 SHOCK ABSORBER, SWINGARM
Filling the dam�er with nitrogen
-
Screw in screw
O
by approx. 2 rotations but do not tighten.
Info
The piston rod is fully extended.
-
Clamp the special tool in the vise.
I
Filling tool (T170S1) (
!!l
p. 300)
Connect the special tool to the pressure regulator of the filling
cylinder.
I
Filling gas - nitrogen
- Adjust the pressure regulator.
Guideline
I
Gas pressure
I
1 0 bar (145 psi)
-
Position the damper in the special tool.
✓ The hexagonal part of the tap handle f) engages in the
hexagon socket of the filling port screw.
-
Open filler tap Ci).
-
Fill the damper for at least 15 seconds.
Guideline
I
Gas pressure
•
Info
I
1 0 bar (145 psi)
I
Watch the pressure regulator dial.
Make sure that the damper is filled to the specified
pressure.
-
Close the filling port screw using tap handle f).
-
Close spigot
0
and take the damper out of the special tool.
-
Tighten the filling port screw.
Guideline
Screw, reservoir fill-
M5
ing port
3 Nm (2.2 lbf ft)
41
77