201701-10
6 FORK, TRIPLE CLAMP
Loosen the screw cover
C,.
Mounting tool (T14047) (!!:,!Ip. 299)
Info
The cartridge cannot be taken off yet.
Unclamp the fork leg.
Slide the outer tube down. Drain the fork oil.
Clamp the fork leg with the axle clamp.
Release hydrostop unit
0
and remove it.
Info
Do not use an impact wrench.
Place a pan underneath since oil will run out.
Remove the cartridge from the fork leg.
Pressing tool (T14051) (
a
p. 299)
•
Info
I
Removing the O-ring seat from the cartridge usually
requires the application of considerable force.
Remove dust boot (D.
Remove fork protector ring t).
•
Info
I
The fork protector ring does not necessarily need to
be removed for repair work.
19