Closed
Pressure
Equallze
pressure
9 SHOCK ABSORBER, SWINGARM
When the pressure gauge reaches the required value, turn
control lever
Damper
8
to Pressure.
Guideline
0 bar
✓ Oil is pumped into the damper.
✓ The pressure gauge increases to the required value.
3 bar
When the pressure gauge reaches the required value, turn
control lever
Damper
8
to Vacuum.
Guideline
3 bar
✓ The pressure gauge drops to the required value.
0 bar
When the pressure gauge reaches the required value, turn
control lever
Oil reservoir
0
to Vacuum.
Guideline
0 bar
✓ The vacuum gauge drops to the required value.
8 mbar
When the vacuum gauge reaches the required value, turn
control lever
Oil reservoir
0
to Equalize Pressure.
Guideline
1
s mbar
✓ The pressure gauge drops to the required value.
0 bar
When the pressure gauge reaches the required value, turn
control lever
Damper
8
to Pressure.
Guideline
0 bar
✓ Oil is pumped into the damper.
✓ The pressure gauge increases to the required value.
3 bar