21 IGNITION SYSTEM
CR
1
�6.3mm
P00023-10
Stator winding - check the short circuit to ground (terminal 31)
Measure the resistance between the specified points.
21.4
21.5
250
Alternator, connector
CR
pin
1
- Measuring point Ground, wiring harness/frame
I
Resistance
I
oo
n
If the indicated value does not correspond to the required value:
-
Change the stator.
Removing the stator and crankshaft ROSition sensor
Condition
The alternator cover has been removed.
-
Remove screws
O.
Remove the retaining bracket.
-
Remove screws
8.
-
Remove cable support sleeve
@)
from the alternator cover.
-
Remove the stator and crankshaft position sensor from the
alternator cover.
..
..
-
Blow out oil nozzle
O
with compressed air and check that it
is clear.
Guideline
Oil nozzle for
M4
2 Nm (1.5 lbf ft)
alternator cool-
Loctite
®
243
™
ing
D00201-10