FORK, TRIPLE CLAMP 6
-
Remove upper slide bearing
@).
Info
Without using a tool, pull the stack slightly apart
by hand.
-
Take off lower slide bearing
(D.
-
Take off support ring Ci).
-
Take off seal ring
G,.
-
Take off lock ring @.
-
Take off dust boot
(D.
-
Unclamp the fork leg.
Disassembling the air cartridge
Caution
Danger of accidents
Disassembling pressurized parts can cause injuries.
-
The fork is filled with compressed air. Please follow the description provided.
0�
e
/
B03552-10
Preparatory work
-
Disassemble the fork legs. (
a
p. 21)
Main work
-
Remove protection cap
O.
-
Slowly release the pressure from the air cartridge.
•
Info
I
Hold the piston rod in extended position to allow the
air pressure to balance between the positive air cham
ber and the negative air chamber.
-
Remove valve core
8.
-
Clamp the air cartridge.
I
Clamping stand (T14072) (
a
p. 31 0)
-
Remove lock ring
(D.
-
Remove fluid barrier
C,.
-
Heat up thread area of air cartridge
O.
Guideline
1
so
0
c
(122 °F)
-
Loosen seal ring retainer
Cs,.
25