English –
98
11.1 Power Supply
11.1.1 Test of +36 V
Description of 36 V test and batteries
The first CST test is an autotest. This tests that
there is +36 V in to the CCU unit. None of the test
will work if the CCU unit is not rec36 V. If
testing without CST, a multimeter must be used to
measure whether CCU is receiving power when
activating with the key switch.
After turning the key to position 1, CCU will be
powered via the key switch, which is fed via a 5 A
fuse. If CCU cannot detect that it has +36 V, this
fuse must be checked first together with both 150 A
fuses.
A thick red lead goes from battery 1 through the
machine's articulated unit to a 150 A fuse located
in the machine's rear carriage. From this fuse, a
thin red lead goes to a 5 A fuse and from there, a
red lead goes to the key switch via the machine's
articulated unit. A red lead goes back from the key
to CCU on the rear carriage, which is coupled to
CCU B11. If CCU is not receiving power, this circuit
must be checked. CCU must also be connected to
GND and it is via CCU B12. If CCU cannot detect
+36 V, the GND connection must also be checked
(reference 0 V).
Connector B at CCU
B11: Keyswitch
B12: Reference 0V
2
1
2
1
2
1
CCU
CCT001
FU3
FU1
FU2
Keyswitch
The machine’s front end.
The machine’s
rear end.
Batt 3
Batt 2
Batt 1
BATTERY
BATTERY
BATTERY
GND
CCU +36V IN
B:11 Power
B:12 GND
5A
Power to machine
150A
Battery
Battery
Battery
150A
Key
5V power supply
36V power supply
Power supply
CST Autotest
Summary of Contents for 967187001
Page 1: ...Workshop manual Rider Battery English ...
Page 2: ......
Page 28: ...English 28 6 5 Exploded View Drawing Cutting Deck Basic dismantle assembly ...
Page 62: ...Repair Work English 62 4 Assemble the new baffle plate 5 Refit the spring and contact ...
Page 143: ......
Page 144: ...2015W44 115 75 74 26 ...