English –
113
Ohm
GND
Common point
Connector A at CCU
A4: Charger in
Charger
Miscelaneous
CST Autotest
GND
Common point
VDC
Battery charger connector
11.5 Miscellaneous
11.5.1 Test of Charger
Manual test without CST can also be carried
out with the help of the text below.
Test with CST check of signal with charger
connected.
1
CCU A:4 is an input signal indicating that the bat-
tery charger is connected. In the connector mount-
ed on the battery charger cable is a strap between
pins 3 and 4. In the connector mounted on the
machine, +5 V is connected to pin 3 orange lead
and to pin 4, a green lead is connected to CCU.
2
Connect a battery charger to the machine. Activate
the machine and measure the green lead at A4. It
should read +5 V if OK.
If there is no voltage on the green lead on connec-
tor A, measure the connector for engaging the bat-
tery charger on the machine so that there is +5 V
on the orange lead's connector, checking also that
the green lead is attached.
Summary of Contents for 967187001
Page 1: ...Workshop manual Rider Battery English ...
Page 2: ......
Page 28: ...English 28 6 5 Exploded View Drawing Cutting Deck Basic dismantle assembly ...
Page 62: ...Repair Work English 62 4 Assemble the new baffle plate 5 Refit the spring and contact ...
Page 143: ......
Page 144: ...2015W44 115 75 74 26 ...