English –
90
Connector C
(Green)
Function
Output
Max in/output
C:1
Connection of
future internal
functions in CCU,
reserve 1.
-
-
C:2
+5 V reserve,
short-circuit pro-
tected output
50mA.
+5 V
50 mA
C:3
Input: (ISP_Re-
set_1) signal used
for any program-
ming problems.
-
+40 V
C:4
Input: (ISP_
BOOT_1) signal
used for any pro-
gramming prob-
lems.
C:5
GND
-
C:6
Input for measur-
ing outgoing cur-
rent from battery,
negative terminal.
+40 V
C:7
Output activation
of main relay.
1 A
C:8
Connection of
future internal
functions in CCU,
reserve 2.
-
C:9
Connection of
future internal
functions in CCU,
reserve 3.
C:10
Input for measur-
ing outgoing cur-
rent from battery,
positive terminal.
+40 V
C:11
Connection of
future internal
functions in CCU,
reserve 4.
-
C:12
Connection of
future internal
functions in CCU,
reserve 5.
Description of electrical system