English –
107
CST Autotest
During this trouble shooting we assume that
+5 V is OK.
11.2 Switches
11.2.1 Test of Cutting Deck
If the test fails, check that the switch turns on when
the cutting deck is activated.
If there is +5 V at the microswitch on the gray lead,
the gray lead must be measured where it goes into
CCU on connector A:1 so that it is +5 V there too.
If not, the gray lead from the connector on CCU to
the microswitch must be checked so there is not
a break somewhere on the stretch as illustrated
below.
Cuttingdeck on switch 1
Cuttingdeck on switch 1
VDC
GND
Common point
Connector A at CCU
A1: Lift SW
Ohm
GND
Common point
Seat
Cutting deck
Switches