background image

UltraScan PRO Supplemental Manual for EasyMatch QC Ver. 2.0 

 

 

53

 

When You Need Assistance

 

If you need for technical or sales assistance on applications, troubleshooting, , service, warranty, 
accessory pricing and more, please contact the office nearest you: 
 

For the Americas, 

[email protected]

 

 

For Asia, 

[email protected]

 

 

For Europe, 

[email protected]

 

 

For India, Middle East and Africa, 

[email protected]

 

 

For all other regions, 

[email protected]

 

Additionally, our global support website offers 24/7 assistance with a library of information on various 
color measurement and appearance topics such as applications, instrument operation, and 
troubleshooting. The HunterLab global support website is located at 

support.hunterlab.com

 

For personalized assistance, go to 

support.hunterlab.com

 and locate th

Create A Ticket

 button on the 

menu. A subsequent form gathers information on your request for response from our Customer 
Experience Teams around the globe.  

 

 

Summary of Contents for UltraScan PRO

Page 1: ...UltraScan PRO Supplemental Manual for EasyMatch QC Hunter Associates Laboratory 11491 Sunset Hills Road Reston Virginia 20190 USA www hunterlab com A60 1017 656 Manual Version 2 0...

Page 2: ...Hunter Associates Laboratory Inc Windows is a registered trademark of Microsoft Corporation in the United States and other countries Duraflect Spectraflect and Spectralon are trademarks of Labsphere...

Page 3: ...Multi Mode 18 Sensor Setup Mode UV Filter 19 Haze Measurements 21 ULTRASCAN PRO MAINTENANCE AND TESTING 25 Running the Repeatability Test 25 Running the Green Tile Test 25 Running the Didymium Filter...

Page 4: ...UltraScan PRO Supplemental Manual for EasyMatch QC Ver 2 0 4 Transmittance 42 Other51 WHEN YOU NEED ASSISTANCE 53 INDEX 55...

Page 5: ...Scan PRO Note Dropping the instrument or using it in a manner not specified by the manufacturer may impair the protection afforded by the equipment Danger of electric shock if liquids are spilled and...

Page 6: ...propriate clamp position for standardization in this position both the light trap and white tile may be placed at the reflectance port by simply pulling back the spring loaded head of the clamp A magn...

Page 7: ...aScan PRO sphere contains a specular exclusion port door which is closed during specular included and transmittance measurements and opened during specular excluded measurements The position of the do...

Page 8: ...s Automated UV Control The UltraScan PRO performs a Ganz Griesser calibration which uses a 400 nm UV filter to achieve and maintain the proper ratio of the energy in the UV region of the electromagnet...

Page 9: ...the retroviewer switch on the top left of the sensor about halfway back The sample is illuminated and an image appears on the screen on the top of the sensor If necessary adjust the door above the scr...

Page 10: ...ing standardization in a transmittance mode Fluorescent standard used to calibrate the position of the UV filter Green tile placed at the reflectance port with pegs in the guidance holes to check inst...

Page 11: ...the computer to a USB to serial adapter and then the serial cable to the instrument Note The UltraScan PRO should be lifted from under the base plate near the center of the unit It should not be carr...

Page 12: ...nd you may skip to Step 5 Otherwise continue with Step3 3 Select the Easy Match QC Icon or from Windows go to START RUN EZMQC_MENU and OPEN The following screen will be shown Figure 9 EasyMatch Instal...

Page 13: ...ware START PROGRAMS HUNTERLAB EASYMATCH QC 2 A warning message to activate the license will be displayed as shown in the Figure below Note EasyMatch QC functions are unavailable before key activation...

Page 14: ...ace the thumb drive with the SoftKey License in the USB port b From the CHOOSE AN OPTION page Figure 13 select KEY FILE skl c Browse the USB to find the SoftKey License skl file then click ACTIVATE d...

Page 15: ...ed to the Install Configure command in the Sensor menu and install a new sensor 2 The Sensor Manager appears first Figure 15 Sensor Manager 3 Select ADD SENSOR to install a new sensor The Setup Sensor...

Page 16: ...ort sample clamp and slide it into place at the reflectance port Depress the back button to slide the clamp all the way in Depress the front button to move the sample clamp up against the sphere Cover...

Page 17: ...kept at the reflectance port When the instrument is to be used for transmittance measurements of liquids a clear liquid distilled water for water based samples toluene or benzene for resins or mineral...

Page 18: ...LABLE MODES box Click on the first mode you wish to use and then click the INCLUDE button to move the mode from the Available Modes box to the Selected Modes box Only modes that are similar enough to...

Page 19: ...he difference is acceptable under your measurement method you may measure your samples with the door open This test should be repeated if the instrument is moved to a new location Sensor Setup Mode UV...

Page 20: ...ue matches assigned WI Ganz value for the Fluorescent standard This UV CAL filter position is fixed and user set until the next UV Calibration UV Filter Custom can create one of more UV Filter states...

Page 21: ...olerable limits for your application use spot 4 for UV filter calibration from this point on and order a new fluorescent standard HL A02 1011 126 calibrated Note If you choose to employ the calibrated...

Page 22: ...n Click the radio button next to the ILLUMINANT OBSERVER combination you wish to use Then click OK 4 STANDARDIZE the instrument in TTRAN mode There are three parts to standardization for haze measurem...

Page 23: ...MEASUREMENTS READ SAMPLE clicking the READ STANDARD or READ SAMPLE button on the toolbar or pressing F2 or F3 The following prompt appears 6 Place your sample against the transmission port the hole i...

Page 24: ...calibration tile with the light trap Click READ Figure 29 Read Sample with Light Trap 8 When the instrument takes the reading you may be prompted to ENTER AN ID for the measurement as usual After you...

Page 25: ...he instructions given in the SENSOR MENU DIAGNOSTICS section to run the repeatability test that is built into EasyMatch QC Running the Green Tile Test The green tile is not used during the standardiza...

Page 26: ...shes or instrument repeatability has become unacceptable it must be replaced CAUTION Replace only with a specified xenon flash lamp assembly HL D02 1012 222 Figure 32 Source Lamp Assembly Before you a...

Page 27: ...screws are captive within the instrument cover housing and cannot be removed 5 Loosen the thumb screw on the inner panel bezel Figure 34 Inside Screws 6 Remove the front cover from the instrument and...

Page 28: ...aScan PRO Supplemental Manual for EasyMatch QC Ver 2 0 28 Figure 35 Remove Front Cover 7 Remove the two screws and cover from the lamp housing using a Phillips head screwdriver Figure 36 Lamp Cover Sc...

Page 29: ...0 29 Figure 37 Remove Lamp Housing 8 Unplug the two white connectors of the lamp assembly by squeezing the latches on the sides of the connectors Figure 38 Unplug White Connectors 9 Release the three...

Page 30: ...trument and tighten the two front screws as well as the inner bezel thumb screw 16 Turn the UltraScan PRO power on 17 Standardize the instrument Replacing the Fuses The fuses are located on the back p...

Page 31: ...use Holder 4 Remove the fuses and replace with new ones Note Use only the fuse specified above for your instrument or one which is identical in type voltage rating and current rating Otherwise there m...

Page 32: ...troviewer Lamp Part To change the view lamp 1 Disconnect the UltraScan PRO from its power source 2 Wait two minutes for complete discharge of the capacitors 3 Disengage and remove the sample clamp 4 L...

Page 33: ...g the harnesses which connect the indicator lights and the macro button to the front cover Figure 46 Front Cover Removal 7 Remove the view lamp assembly and replace it with a new one Be sure not to to...

Page 34: ...g the sphere The transmittance compartment should be closed and the sample clamp placed against the reflectance port when the instrument is not in use The sphere is coated with Spectraflect which can...

Page 35: ...instrument should be connected to a stable instrument grade power line If other equipment is connected to the same power line a transient power surge may be produced when the other equipment is turned...

Page 36: ...5VAC at 110V input power or more than 10VAC at 220V input power may indicate a difference in ground wiring and can damage the instrument and or the computer Check the wiring and take other steps as n...

Page 37: ...nterval 5 nm Wavelength Accuracy 0 75 nm Photometric Range 0 150 reflectance or transmittance Note Every attempt at accuracy is made but specifications are subject to change without notice Note Use of...

Page 38: ...UltraScan PRO Supplemental Manual for EasyMatch QC Ver 2 0 38...

Page 39: ...that is covered with glass The glass insert protects the inside of the instrument from sample and airborne particles Figure 48 Glass Port Insert Port Plate Diffuse port Sample Cup Holder D02 1003 739...

Page 40: ...lamps allows good positioning of the sample at the reflectance port Sample Holder Reflectance Preform Holder D02 1011 841 This option provides an adjustable holder for measuring translucent and opaque...

Page 41: ...2 931 The Semi Micro Port Plate with Powder Holder provides a holder plunger and special port plate that allow the measurement of small quantities approximately 0 4 cc of packed powder Requires MAV Me...

Page 42: ...Transmittance Cell Holder Round Glass Vials 24mm D02 1011 550 This option provides a transmittance holder for 24mm ID 27 mm to 30 mm OD round glass vials with volumes of 20 40 or 60 mL Vials are avai...

Page 43: ...ow Through Cell The dimensions and volumes of the various flow through transmittance cells are as shown in the table The flow through transmittance cell can be used with manual or automated pumps such...

Page 44: ...r liquids Select one or more of the available precision cell holders by matching cell holder specifications with the desired glass or plastic analytical cells Analytical cells are purchased separately...

Page 45: ...on compartment Cell Holder Small Volume Cell for Transmittance D02 1011 886 Small Volume Cell with Two Screw Caps A13 1011 613 This option provides a holder for a cylindrical small volume transmittanc...

Page 46: ...re Opening Transmittance Cells 50mm 33mm 20mm 10mm The Transmittance cell option provides an optically clear glass cell with a fixed path length of 50 mm 33 mm 20 mm or 10 mm Transmittance cells are r...

Page 47: ...ith 2 screw tops D12 1011 890 33 Screw Top Transmittance Cell 33mm with 2 screw tops D12 1011 891 50 Screw Top Transmittance Cell 50mm With 2 screw tops D12 1011 892 Transmittance Cells with Two Screw...

Page 48: ...or Total Transmittance measurements Figure 66 Transmittance Sample Clamp Cell Holder Transmittance with Spill Tray D02 1011 568 The Transmittance Cell Holder with Spill Tray when installed in the tran...

Page 49: ...regular transmission measurements Used in combination with the Cell Holder Base Assembly USPRO and USVIS PN D02 1016 956 or Vista PN D02 1017 224 sold separately A starter kit of three PMMA plastic c...

Page 50: ...older Ultra Micro Plastic Cells Ultra Micro Plastic Min 0 6mL Max 0 7mL 12 50 x 12 50 mm 0 492 x 0 492 in Brand 759200 D02 1017 048 Cell Holder Glass Macro Cells Macro Glass Min 2 5mL Max 4 5mL 12 50...

Page 51: ...ceiver Ring purchased separately and seals the sphere from the transmission compartment Insert 6mm Aperture with Holder D02 1019 350 The 6mm Aperture Insert provides a magnetically attached insert to...

Page 52: ...UltraScan PRO Supplemental Manual for EasyMatch QC Ver 2 0 52 Figure 70 Foot Switch...

Page 53: ...nd Africa IMEASupport hunterlab com For all other regions Support hunterlab com Additionally our global support website offers 24 7 assistance with a library of information on various color measuremen...

Page 54: ...UltraScan PRO Supplemental Manual for EasyMatch QC Ver 2 0 54...