LAMINATOR SET-UP __________________________________________________________________________
If a process requires heat, press ON the heaters approximately 45 minutes before use to ensure that the rollers
are at the correct operating temperature.
CHECKING OPERATION
After you are familiar with the control panel’s buttons, check all operations.
n
Check the Motor and Footswitches.
•
Press the motor On/Off button once, the corresponding LED should be lit.
•
Push the motor Up Arrow and the speed readout should increase in number and motor speed.
•
Press the Down Arrow and the speed readout should decrease in number and motor speed.
n
Check the Heater Controls.
•
Press the Top Heater On/Off button once, the corresponding LED should be lit.
•
The readout will display the ambient temperature.
•
Press the top heater Up Arrow to see the temperature set point. Watch the readout for 5 minutes to verify that
the temperature increases.
•
Press the top heater On/Off button again once, the corresponding LED should not be lit.
•
Repeat this procedure for the Bottom Heater.
n
Check the Emergency Stop Buttons.
•
Press one of the Emergency Stop Buttons and the laminator will shut down.
•
Rotate the Emergency Stop Button clockwise to reset.
•
Press the Power Standby Button. The laminator will turn back on. Check to make sure the corresponding LED is
lit. Repeat this procedure with all four Emergency Stop Buttons.
þ
WARNING! If your laminator does not operate correctly, contact Technical Service immediately.