User Manual of HBK-1100KI Network Keyboard
33
settings to other camera(s).
Configuring Record Settings
1.
Configuring Advanced Settings
On the Record Settings interface, select the camera for configuration. Click Advanced to enter the Advanced
Settings interface where you can configure the pre-record, post-record, expired time, redundant record, record
audio, etc.
Pre-record: The time you set to record before the scheduled time or event. For example, when an alarm triggered
the recording at 10:00, if you set the pre-record time as 5 seconds, the camera records it at 9:59:55.
Post-record: The time you set to record after the event or the scheduled time. For example, when an alarm
triggered the recording ends at 11:00, if you set the post-record time as 5 seconds, it records till 11:00:05.
Expired Time: The expired time is the longest time for a record file to be kept in the HDD, if the deadline is reached,
the file will be deleted. You can set the expired time to 0, and then the file will not be deleted. The actual keeping
time for the file should be determined by the capacity of the HDD.
Redundant Record: Enabling redundant record or capture means you save the record and captured picture in the
redundant HDD.
Record Audio: Choose “yes” to record the sound, “no” to record the image without sound.
2.
Editing Recording Schedule
On the Record Settings interface, click Edit to enter record schedule setting interface.