9.2.3 Shock absorbers
The shock absorbers are intrinsically mainte-
nance-free.
The damping effect will decrease after long peri-
ods of use and long intervals of use.
The shock absorbers and their attachment need to be
regularly checked for oil leaks, damage, ageing, breakage
and material fatigue.
Servicing work must only be carried out by qualified
specialists.
1
2
Maintaining the shock absorbers
1. Attachment
2. Shock absorbers (marking)
►
►
Check the attachments for secure fit
and tighten if necessary.
►
►
Check the shock absorbers visually for oil leaks.
►
►
If the damping effect reduces or if there are visible oil
leaks, replace the shock absorbers.
Use only genuine spare parts, see designation / article no.
on the shock absorber.
9.2.4 Eccentric tension locks
The eccentric tension locks must be regularly
checked for a firm fit (at least every 6 months or
5,000 km).
Have loose attachments repaired by a specialised
workshop.
1
2
3
3
2
1
Adjusting the eccentric tension locks
1. Eyelet
2. Thread
3. Hook
►
►
Unlock the eccentric tension locks.
►
►
Use the thread to turn the eyelets OPEN or CLOSED -
depending on whether you want to fasten or loosen them.
►
►
Place the eyelets onto the hook and check that
the eccentric tension locks fit firmly and that
the cargo bed or ramp wall is firmly attached;
adjust if necessary.