16
The User Interface
Table 5: Receive code (RxCode) messages and corrective actions
Numeric
RxCode
Message Displayed
Comments
0
The receiver is not connected
Please make sure that the Indoor Receive Unit is connected to the
Gateway via the USB cable. If the cable is connected and you still
see this message, use the following steps for troubleshooting:
• Make sure the power supply is correct. The power supply should
be Part # 1031105-0001.
• Try power-cycling the DW4020 by unplugging the power cord
from the wall outlet and then plugging it back in.
• Try using a different USB cable.
• If none of the above resolve the issue, you may need to replace
the Indoor Receive Unit.
1
The receiver is in pointing mode
This condition indicates that the installer is performing antenna
pointing. In this mode, the transmitter is disabled for safety
reasons since the installer is working near the dish. If this occurs
during normal operation, try power-cycling the DW4020 by
unplugging the power cord from the wall outlet and then plugging
it back in.
2
The receiver is in factory or NOC mode
This status is for DW4020 testing purposes only. You should never
see it. If this occurs during normal operation, try power-cycling the
DW4020 by unplugging the power cord from the wall outlet and
then plugging it back in.
3
The receiver is not locked to a signal
If the DW4020 had been operating previously, this status is
probably due to inclement weather conditions and will be
corrected when the weather improves. This condition can also
indicate that the IRU is unable to receive the signal from the NOC.
This is also associated with a signal level less than 30. This
occurs if there is a weather outage at the user location, a NOC
outage due to inclement weather or other reasons, a misaligned or
faulty antenna, or faulty cabling. If this keeps happening under
normal weather conditions, make sure the power supply is correct.
The power supply should be Part # 1031105-0001. If the power
supply is correct, try power-cycling the DW4020 by unplugging the
power cord from the wall outlet and then plugging it back in.
4
The receiver is locked to the wrong network
This condition should only be seen during installation and occurs
when the receiver is locked to a signal, but the signal ID does not
match the ID that was assigned to the user during commissioning
or the ID that was entered by the installer during manual pointing.
If this occurs during normal operation, it may be due to the user
changing acquisition parameters, including frequency and/or
location of satellite, or the antenna becoming misaligned.