Chapter 4—Setup Adjustments
HJT Model 100 User's Guide
4-15
Figure 4.0-6 Vertical Rotation Distortion
Figure 4.0-7 Skew Distortion-Vertical Centerline Tilted
To correct for Rotation:
1. Select the Standard Crosshatch test pattern.
2. Select
S
KEW
/R
OTATE
from the G
EOMETRY MENU
.
3. Toggle the RGB
KEY
to select G only.
4. Use the H
IDE KEY
and hide R and B.
5. Use the up/down arrow keys to correct for vertical rotation.
6. Press
E
SCAPE
/E
NTER
to exit.
To correct for Skew:
1. Select the Standard Crosshatch test pattern.
2. Access
S
KEW
/R
OTATE
from the G
EOMETRY MENU
.
3. Toggle the RGB
KEY
to select G only.
4. Use the H
IDE KEY
and hide R and B.
5. Use the left/right arrow keys to correct for horizontal skew.
6. Press
E
SCAPE
/E
NTER
to exit.