Appendix A—Extron Switcher Interface to Model 100
Appendix A-2
Hughes-JVC Technology Corporation
In addition, all Extron switchers must be configured to use HJT protocols and
19200 baud rate (Hughes-JVC emulation). This is usually done at Extron and a
“Configured for Hughes-JVC” sticker is placed on the back of the unit. The Extron
Service Manual for each unit describes how to reset the system to a state
compatible with the HJT protocol, if necessary.
A.2 Extron User’s Manual Inaccuracies
Early revisions (up to Rev C) of the Extron Model 8 and 10 User’s Manual,
describe incorrect configuration procedures for setting Master mode. Specifically,
the description shows that when switch 4 of the address switch block is set to the
closed position it enables the configuration mode. The correct position for this
switch is the opened position. A correct example for setting the Model 8 and 10
switchers is detailed below.
A.3 Key Operational Differences Between Models
The switcher firmware for Model 8 and 10+ function differently from the Model 4
firmware. Switching on the Model 8 and 10+ always occurs independently of the
projector. For example, when a channel switch is pressed on the Model 8 and
10+, the switcher automatically selects that channel after a short time period (~2
seconds). This channel switching occurs even if a projector is not connected to a
switcher. When a projector is connected to a Model 8 or 10+ (and the
communication interface is working properly) and a channel switch is pressed, the
projector normally changes the channel immediately (before the 2-second time
period has expired).
On the Model 4LD, there is no automatic channel switching. Channel switching is
prohibited unless commanded by the projector. If the communication interface
between the switcher and projector is not functioning properly, no channel
switching occurs.
A.3.1 Switcher to Projector Configuration Example
The following provides an example of how to configure an Extron Model 8
Switcher to a HJT Model 100 Projector:
1. Connect the switcher to the Model 100, Port B.
2. Set Comm. Setup to Port B.
3. Set the Port B baud rate to 19200.
4. Turn power off at the remote control (or PC).
5. Wait at least one (1) minute, for the system to reach an “Off” state
from Step 4, then toggle the circuit breaker on the rear panel to Off
and then back to On.
6. Verify that the Model 8 Switcher internal dip switches are set to
Hughes Emulation and the baud rate is set to 19200
(use the Extron manual to confirm this).
7. Turn power on to the Model 8 Switcher.
8. Set the Model 8 external “address” dip switch #4 to the open position.
Summary of Contents for 100
Page 6: ...Table of Contents vi Hughes JVC Technology Corporation ...
Page 10: ...Safety Information x Hughes JVC Technology Company ...
Page 16: ...Chapter 1 Introduction 1 6 Hughes JVC Technology Company ...
Page 55: ...Chapter 4 Setup Adjustments HJT Model 100 User s Guide 4 3 ...
Page 102: ......
Page 108: ...Chapter 6 System Specifications 6 4 Hughes JVC Technology Corporation ...
Page 118: ...Appendix B Export Import Procedures Appendix B 6 Hughes JVC Technology Corporation ...
Page 126: ...Chapter 7 Glossary Glossary 8 Hughes JVC Technology Corporation ...