Configuration manual EGS(H)41
27
10
Error table
Error message Description
Dg_Intern
[FFxx]
Device error
Dg_Iov
[0601, FE01
Overcurrent in the switch 1 or switch 2
Dg_Sw1Dr
[0602, FE02]
Broken wire switch 1
Dg_Sw2Dr
[0603, FE03]
Broken wire switch 2
Dg_TempMain
[0604, FE04]
Overtemperature in device
Dg_TempKK
[0605, FE05]
Overtemperature in switch
Dg_Temp230V
[0606, FE06]
Overtemperature in power supply unit “Option HV”
Dg_ExtOv
[0607, FE07]
Max. permissible supply voltage exceeded
Dg_n_Fatal
[0608, FE08]
Non-permissible high speed
Dg_ExtUv
[0609, FE09]
Below lowest permissible supply voltage
Error
[FExx]
Error
FatalError
[FFxx]
Fatal error
Error category:
Error:
The switches S1, S2 and Diag are opened.
To reset to the normal state interrupt the power supply via the reset input or click 'Delete error'
in the software 'EGS41Pro'.
Fatal error:
The switches S1, S2 and Diag are opened.
To reset to the normal state click “Delete error” in the software “EGS41Pro”.
The 'Delete error' command initiates a restart. If the error persists the device remains in the er-
ror state.
The device enters a 'safe state' in the event an error or fatal error occurs. In addition, the error
causing the problem is displayed.